何莲凤
摘要:当住宅、办公楼配电线路发生短路、断路、接地、过载等电气故障时,会造成供电中断。电工能否准确、迅速排除故障,能否缩小停电区域和缩短停电时间,取决于电工查找故障点的能力,作者根据工作实践,探索、总结电气故障的现象、判断和查找方法,以提高准确、迅速查找故障点能力,提高排除电气故障的效率。
关键词:电气故障的现象、判断和查找方法;迅速查找故障点能力;排除电气故障的效率
Abstract: when the residential, office building distribution circuit breaker, short-circuited, grounding, overload and electrical fault, can cause the power failure. Electrician can be accurate, fast resolved the problem, can narrow areas and shorten the time power blackout, depends on the ability of the fault point search electrician, the author according to the work practice, explore and summarized the electrical fault phenomenon, judgment and search method, in order to improve the accurate, fast find fault point ability, improve the efficiency of the electrical fault ruled out.
Keywords: electrical fault phenomenon, judgment and search method; Quickly find fault point ability; Excluding electric fault efficiency
中图分类号:U224.3+1文献标识码:A文章编号:
当住宅、办公楼配电线路发生电气故障后,我们首先要根据断路器和漏电开关的状态初步判断发生了什么电气故障:当断路器跳闸,可判断发生了过载或短路故障;当漏电开关跳闸,漏电指示按钮未彈起,可判断发生了过载或短路故障;当漏电开关跳闸,漏电指示按钮弹起,可判断发生了接地故障;当断路器、漏电开关不跳闸,用电器不能正常工作,可判断发生了断路故障。但具体发生了哪种故障,故障点在哪,还是需要人工进行分析和判断。
一、断路故障
1、断路故障的现象
断路故障最基本的表现形式是回路不通,通电后电气设备不能工作。
2、断路判断依据
(1)、电路中的电气设备没有电压降,电源电压全部降落在断路点两端。
(2)、单相回路中,断路点两端电位不等,一端电位高(用试电笔检测试电笔发亮),一端低电位(用试电笔检测试电笔不发亮)。
3、断路故障查找
当用电设备不能工作或不能正常工作,应先以出现故障线路的开关为节点进行检查,切除该开关,检查该开关进线侧相电压、线电压,检查电源是否缺相,零线是否断线。……