唐友云,李剑群,张大华,周亚斌
(中国石油兰州润滑油研究开发中心,甘肃兰州730060)
PDSC法研究在用汽油机油氧化安定性
唐友云,李剑群,张大华,周亚斌
(中国石油兰州润滑油研究开发中心,甘肃兰州730060)
用高压差示扫描量热(PDSC)程序升温法和恒温法对在用汽油机油的氧化安定性进行了研究。结果表明随着行车里程数的增加,在用汽油机油的起始氧化温度(Ton)和氧化峰值(Tp)不断降低,氧化诱导期时间(OIT)不断缩短,这一结果与油品酸值的增加趋势和碱值的降低趋势相符,均反映了油品在行车试验中的氧化衰败过程。因此PDSC程序升温法和恒温法均可用于在用汽油机油的氧化安定性评价,但是程序升温法与恒温法相比,具有测试条件选择简单的优势,故在对在用汽油机油的氧化安定性进行评价时推荐使用程序升温法。
氧化安定性;在用油;高压差示扫描量热
Abstract:Oxidation stability of the used gasoline engine oil was studied by isothermal and programmed ramp methods of Pressure Differential Scanning Calorimetry(PDSC).The result showed that the oxidation onset temperature(Ton),oxidation peak temperature(Tp)and oxidation induction time(OIT)reduce with the increase of mileage.These results are consistent with the change trend of the basic number and acid number,which indicate the isothermal method and programmed ramp method are effective in oxidation stability evaluation.Moreover,comparing with the isothermal method,the programmed ramp method has the advantage of simple test conditions.Thereby,the programmed ramp method is recommended when oxidation stability is evaluated by PDSC.
Key words:oxidation stability;used oil;PDSC
氧化安定性是润滑油的一项重要性能指标,它决定润滑油在使用过程中是否容易变质,直接影响润滑油的使用寿命和高温性能,因此一直倍受人们的关注。氧化安定性的评价方法较多,如旋转氧弹试验(ASTM D2272),开口试管氧化试验(ASTM D943)等等。但这些方法大都存在着操作繁琐、样品用量大、试验时间长和重复性较差等缺点,而加压差示扫描量热法(PDSC)测定润滑油的氧化安定性具有微量、快速、准确等优点,是评价润滑油基础油氧化安定性、筛选抗氧剂十分有效的方法,相关方面的研究已有大量的文献报道[1-9]。……