汽轮发电机组基础的大比例模型抗震实验研究

2014-04-21 00:36:00赵刚杨洪镇屈铁军
城市建设理论研究 2014年11期

赵刚 杨洪镇 屈铁军

摘要:为了研究100MW汽轮发电机组的基础,本文按照1:5的比例设计和制作试验模型。基础的结构形式近似为框架结构。通过进行8度设防地震和8度罕遇地震作用下的拟动力试验,得到了基础结构的地震反应。试验表明,基础在8度地震作用下仍处于安全状态。

关键词:基础、抗震性能、拟动力实验

中图分类号:TB857文献标识码: A

Large scale test of the anti-seismic performance of turbine generator foundatin

Zhao gangYang hong zhenQu tie jun

(College of Architecture and Civil Engineering,North China University of Technology)

Abstract:In order to research a 100MW steam-turbine generator foundation,the paper design and build a 1 ∶ 5 scale testing model.The foundation takes a similar frame construction.The pseudo-dynamic tests under intensity 7 frequently and rarely earthquake are carried out and the characteristics of earthquake response are studied.The results indicate that the foundation has preferable seismic capability during the earthquake.

Keywords: foundation; earthquake response; pseudo-dynamic test

1、引言

汽轮发电[ [基金项目] 北京市属高等学校人才强教计划资助项目

第一作者简介: 赵刚, 硕士研究生. 主要研究方向: 工程抗震,电话13699221052]机组的基座是核电站非常重要的工程之一,该基座在震中和震后的安全状况与核电站的能否正常运行息息相关,因此保证基座在地震中结构的基本功能非常重要。汽轮发电机组设备质量巨大,运行过程中基座的受力情况复杂。虽然,近年来关于汽轮发电机组基座的抗震安全性进行了较多的研究,但研究手段仅限于理论计算或小比例模型实验,文献[1]和[2]中实验模型的比例是1:10,文献[3]中实验模型的比例是1:8。

汽轮发电机组基座的原形尺寸较大,由于振动台试验受振动台面尺寸的限制,只能进行很小比例的模型试验。小比例模型做抗震实验特别是罕遇地震作用下的抗震实验,由于结构已进入塑性状态,模型与原型的相似条件很难满足,实验数据误差较大。且比例太小,实验数据的精度也不能保证。拟动力试验可以弥补振动台实验的上述缺点,并且在实验工程中可以观察模型的整个破坏过程,所以本文选用拟动力试验方法研究基座的抗震性能。……