尿液潜血的临床检验结果分析

2014-10-21 15:55:33谢世红
医学美学美容·中旬刊 2014年7期
关键词:检测

谢世红

【摘要】目的 通过对尿液分析仪检测尿潜血反应和镜检红细胞的结果进行分析比较,探讨尿液潜血干化学分析结果的临床使用价值。方法 选取我院门诊患者留取的尿液120份,分别使用尿液分析仪检验和镜检RBC,观察分析两种红细胞检验的检验效果,记录相关数据,进行统计学分析。结果 尿液分析仪潜血检测的敏感度为91.23%,假阳性率为9.11%,假阴性率为10.12%;本研究检验的120例标本中,尿液分析仪测定为阳性的74例标本,同时用显微镜检查观察到红细胞的有59例,无红细胞的15例;而通过尿液分析仪测的为阴性的有46例,同时显微镜观察有红细胞的7例, 无红细胞的39例。表明在临床检验尿液潜血的检验中使用尿液分析仪联合镜检检验对比单用镜检效果明显(P<0.05),具有统计学意义。结论 显微镜检测和尿液分析仪检测都会因为各种主客观因素的影响而出现一定的误差,但是它们的误差影响因素并不相同,因此在临床检测中,可以将两种检测方式结合使用,以便为患者的身体健康和生活质量提供更多的保障。

【關键词】尿液潜血尿液分析仪镜检

【Abstract】purpose The urine analyzer for detecting the urinary occult blood and microscopic analysis of red blood cell analysis and comparison of the results of urine occult blood, dry chemical analysis results of clinical use value.Method Select 120 urine specimens from the out-patient clinic of our hospital, were used to test and microscopic examination of urine analyzer RBC, observation and analysis of two red cell test results, record relevant data, statistical analysis.Result Occult blood of urine analyzer detection sensitivity is 91.23%, false positive rate 9.11%, false negative rate was 10.12%; in this study, 120 samples of urine analyzer examination, 74 cases were positive, and examined microscopically observed in red blood cells of 59 cases, 15 cases without red blood cells and the urine; analyzer for negative in 46 cases, and 7 cases of microscopic observation of red blood cells, red blood cells of 39 patients with non. That contrast test using urine analyzer combined examination in clinical urine occult blood test in single microscopic effect is obvious (P < 0.05), with statistical significance.Conclusion Microscopic examination and urine analyzer detection will be because of various subjective and objective factors and appear a certain error, but the error factors are not the same, so in the clinical detection, can be used in combination with two detection methods, in order to provide more protection for the patient's health and quality of life.

【key words 】Urine occult blood of urine analyzer examination

【中图分类号】R722.12 【文献标识码】B【文章编号】1004-4949(2014)07-0009-02

引言:尿液分析仪是尿常规检测的手段之一,其简便、快速为临床诊断提供了方便。显微镜检查是目前检测尿液有形成分的主要手段,但其检查耗时费力。为此,本文对120例门诊患者的随机尿样,用尿液分析仪潜血反应和尿液显微镜检查红细胞两种方法进行检验,并对两种方法的符合程度进行比较。……

登录APP查看全文

猜你喜欢
检测
QC 检测
小波变换在PCB缺陷检测中的应用