3D numerical study on flow structure and heat transfer in a circular tube with V-baffles☆

2015-11-01 07:55:42WithadaJedsadaratanachaiNuthvipaJayranaiwachiraPongjetPromvonge
Chinese Journal of Chemical Engineering 2015年2期

Withada Jedsadaratanachai*,Nuthvipa Jayranaiwachira,Pongjet Promvonge

Department of Mechanical Engineering,Faculty of Engineering,King Mongkut's Institute of Technology Ladkrabang,Bangkok 10520,Thailand

Keywords:Periodic flow Tube Laminar flow Heat transfer Pressure loss V-baffle

A B S T R A C T A 3D numerical investigation has been carried out to examine periodic laminar flow and heat transfer characteristics in a circular tube with 45°V-baffles with isothermal wall.The computations are based on the finite volume method(FVM),and the SIMPLE algorithm has been implemented.The fluid flow and heat transfer characteristics are presented for Reynolds numbers ranging from 100 to 2000.To generate main longitudinal vortex flow s through the tested section,V-baffles with an attack angle of 45°are mounted in tandem and in-line arrangement on the opposite positions of the circular tube.Effects of tube blockage ratio, flow direction on heat transfer and pressure drop in the tube are studied.It is apparent that a pair of longitudinal twisted vortices(P-vortex)created by a V-baffle can induce impingement on a wall of the inter-baffle cavity and lead a drastic increase in heat transfer rate at tube wall.In addition,the larger blockage ratio results in the higher Nusselt number and friction factor values.The computational results show that the optimum thermal enhancement factor is around 3.20 at baffle height of B=0.20 and B=0.25 times of the tube diameter for the V-upstream and V-downstream,respectively.©2014 The Chemical Industry and Engineering Society of China,and Chemical Industry Press.All rights reserved.

1.Introduction

Turbulator is a technique for heat transfer augmentation and widely used in the industrial heat exchanger.Heat transfer system in chemical and biochemical industries is often installed with various types of turbulator to increase the efficiency of cooling or heating.The application of turbulators changes drastically the flow field and thus the distribution of the local heat transfer coefficient,leading to higher heat transfer rate.Although heat transfer is increased through the turbulator arrangement,the pressure drop of flow in the tube is also increased due to the turbulator effect.Therefore,turbulator spacing,angle of attack,configuration and height are among the most significant parameters in the design of tube heat exchangers.

Many types of turbulator have been studied,and many baffles or ribs have especially been used in many thermal systems.Flat or curved plated baffle is extensively employed in various applications for stabilizing and directing flow,controlling sloshing or w aves,preventing over flow and mixing enhancement purposes[1,2].An academic study on this topic was firstly reported by Berner et al.[3]w ho reported the effect of baffle presence in a shell and tube heat exchanger model using an approximate two-dimensional model.The turbulent flow and heat transfer between a periodical series of conducting parallel plates with surface-mounted heat sources were reported by Kim and Anand[4].They found that the presence of the plates(as baffles in electronic cooling channels)would affect directly the friction factor and the Nusselt number and lead to an increase in heat transfer rate.Dutta and Dutta[5]carried out both experimental and numerical studies.Their results show effects of inclined baffles on friction loss and heat transfer of turbulent flow in a rectangular channel with constant heat flux on the upper wall.The baffle size,orientation and perforation on the average and local Nusselt numbers were also reported.They found that the size,positioning and orientation of the baffle have significant influence on internal cooling heat transfer.In addition,an optimum perforation density for perforated baffles leads to strong jet impingement phenomenon and maximizes heat transfer.Chen et al.[6]developed a mathematical model for three-dimensional numerical investigation of flow and heat transfer characteristics in cylindrical crystal grow th systems.They reported that a baffle placed between the lower and upper chambers may reduce the flow strength but causes more uniform velocity and temperature distributions in the crystal grow th zone(i.e.upper chamber).Moreover,they emphasized that location;thickness,shape and porosity of the baffle can influence effectively the growth process and should be studied in detail.Li and Braun[7]compared flow configuration and transport mechanisms in rectangular and cylindrical enclosures with and without baffles.They found that the presence of the baffle interrupts directly the wall layer interactions and circumferential partitioning of the flow.Therefore,the transport of mass and energy is reduced in comparison to the case with no baffle.The numerical investigations of laminar forced convection in a three-dimensional channel with baffles for periodically fully developed flow and with a uniform heat flux in the top and bottom walls were presented by Lopez et al.[8].Guo and Anand[9]studied the three-dimensional heat transfer in a channel with a single baffle in the entrance region.

Fig.1.Tube geometry and computational domain of periodic flow.

Numerical studies for both solid and porous baffles in a two dimensional channel for the turbulent flow[10]and for the laminar flow regimes[11,12]were conducted,including the report on similar thermal performance.From the experiment for turbulent channel flow with porous baffles of Ko and Anand[13],the porous baffles are found to present a flow behavior as good as the one with solid baffles.Tsay et al.[14]investigated numerically by using baffles for enhancement of heat transfer in laminar channel flow over two heated blocks mounted on the lower plate.Sripattanapipat and Promvonge[15]studied numerically the laminar periodic flow and thermal behaviors in a two-dimensional channel fitted with staggered diamond-shaped baffles and found that the diamond baffle with half apex angle of 5-10°performs slightly better than the flat baffle.Promvonge et al.[16]also examined numerically the laminar heat transfer in a square channel with 45 degree angled baffle placed on one wall.They reported that a single streamwise vortex flow occurs and induces impinging jets on the wall of the inter-baffle cavity and the baffle trailing edge(BTE)sidewall.Tang and Zhu[17]investigated experimental and numerical for flow of water and heat transfer characteristics in a rectangular channel with discontinuous crossed ribs and grooves.They reported that the overall thermo-hydraulic performance for ribbed-grooved channel is increased by 10%-13.6%when compared to ribbed channel.The effects of wire coil,circular ring and twisted tape on heat transfer and pressure drop were reported[18,19].The highest thermal enhancement factor was found at 1.42 for combined turbulator,circular ring and twisted tape.

Most of the previous investigations on laminar flow have only considered the heat transfer characteristics for various baffle height and spacing ratios for porous,solid transverse or inclined baffles in a channel.In consequence,the study on V-baffles in circular tube has rarely been reported.In the present work,the numerical computations for three-dimensional laminar periodic circular tube flows over a 45°V-baffle pair mounted on two opposite tube positions are conducted with the main aim to examine the changes in the flow structure and thermal performance.The employment of the V-baffle placed periodically is expected to generate a pair of longitudinal vortex flows along the tube and give better mixing of fluid between the core and the wall region to result in higher heat transfer rate in the tube.

2.Computational Models and Numerical Method

2.1.Computational domain

The system of interest is a circular tube with a 45°V-baffle pair placed on opposite positions of tube wall in tandem for in-line arrangement as shown in Fig.1.The flow under consideration is expected to attain a periodic flow condition in which the velocity field repeats itself from one cell to another.The concept of periodical fully stabilized flow and its solution procedure have been described in Ref.[20].The air enters the circular tube at an inlet temperature,Tin,and flows over a 45°V-baffle pair where b is the baffle height,D,the tube diameter(0.05 m in this work),and b/D is known as the blockage ratio,B.The axial pitch,L or distance between the V-baffle cells is equaled to D and L/D is defined as the pitch spacing ratio,P.All case studies were present in Table 1.

Table 1V-baffle tested

2.2.Boundary conditions

Periodic boundaries are used for the inlet and outlet of the flow domain.Constant mass flow rate of air with temperature of 300 K(Pr=0.7)is assumed in the flow direction rather than constant pressure drop due to periodic flow conditions.The inlet and outlet velocity profiles must be identical.The physical properties of the air have been assumed to remain constant at average bulk temperature.Impermeable boundary and no-slip wall conditions are implemented over the tube wall as well as the V-baffle surface.The constant temperature of circular tube wall is maintained at 310 K while the V-baffle plate is assumed at adiabatic wall conditions.

2.3.Numerical models

The numerical model for fluid flow and heat transfer in a circular tube was developed under the following assumptions:

·Steady three-dimensional fluid flow and heat transfer.

·The flow is laminar and incompressible.

·Constant fluid properties.

·Body forces and viscous dissipation are ignored.

·Negligible radiation heat transfer.

2.4.Grid system

The computational domain is resolved by regular Cartesian elements.The inlet and outlet are chosen to be deflected planes with the apex angle of 45°,so that the grid system is more regular and uniform and better fitted with the V-baffles.A grid independence procedure was implemented by using Richardson extrapolation technique over grids with different numbers of cells.The characteristics of four grids with 43200,83200,160000 and 326400 cells are employed in the simulations for getting the grid convergence index[21].The variation in Nu and f values for the 45°V-baffles at B=0.20 and Re=1000 is less than 0.2%when the number of cells increases from 160000 to 326400,hence there is no further advantage in increasing the number of cells beyond this value.Considering both convergent time and solution precision,the grid system of 160000 cells was adopted for the current computational model.

3.Mathematical Foundation

Based on the above assumptions,the flow in circular tube is governed by the continuity,the Navier-Stokes and the energy equations.In the Cartesian tensor system these equations can be written as follows:

Continuity equation:

Momentum equation:

Energy equation:

where Γ is the thermal diffusivity and is given by

Apart from the energy equation discretized by the QUICK scheme,the governing equations were discretized by the second order upwind(SOU)scheme,decoupled with the SIMPLE algorithm,and solved by using a finite volume approach[22].The solutions were considered to be converged when the normalized residual values were less than 10-5for all variables but less than 10-9only for the energy equation.

Four parameters of interest in the present work are the Reynolds number,friction factor,Nusselt number and thermal enhancement

factor.The Reynolds number is defined as

The friction factor,f,is computed by pressure drop,Δp,across the length of the periodic tube,L,as

The heat transfer is measured by local Nusselt number which can be written as

The average Nusselt number can be obtained by

The thermal enhancement factor,η,is defined as the ratio of the heat transfer coefficient of an augmented surface,h to that of a smooth surface,h0,at an equal pumping pow er and given by

where Nu0and f0stand for Nusselt number and friction factor for the smooth tube,respectively.

4.Results and Discussion

4.1.Validation of smooth tube

Verification of the heat transfer and friction factor of the smooth tube without baffle is performed by comparing with the previous values under similar operating conditions.The current numerical smooth tube results are found to be in excellent agreement with exact solution values obtained from the open literature[23]for both the Nusselt number and the friction factor,less than±0.25%deviation as shown in Table 2.The exact solutions of the Nusselt number and the friction factor for laminar flows over smooth tube with constant wall temperature are as follows[23]:

Table 2Validation of smooth tube

4.2.Flow structure

The flow configuration in tested tube with V-baffles on the opposite positions can be displayed by considering the streamline plot as depicted in Figs.2 and 3.Hence,the streamline of the V-baffle module are present at Re=800 and B=0.20.As flow behaviors of the periodic baffled tube flow are not completed by itself in one module used in the computation,several baffle modules are connected together as desired to shed light to its flow characteristics.

From Fig.2,the streamlines in transverse planes at different locations for the V-baffle pointing downstream(called V-downstream)and pointing upstream(called V-upstream)were reported.Fig.3(a)and Fig.3(b)also present the details of streamlines in transverse planes at different axial locations for the V-downstream and V-upstream,respectively.It can be observed that there are four longitudinal vortex flows in the tube.Similarity,two counter-rotating vortices appear on the upper and the lower parts due to baffle symmetry for both the V-downstream and the V-upstream baffles.A closer examination reveals that the V-upstream produces two counter-vortex flows having a rotating direction down to the wall,called “common- flow-down”while the V-downstream gives opposite rotating flow direction,called“common- flow-up”.

Fig.2.Streamlines in transverse planes at different axial locations for(a)V-downstream and(b)V-upstream at Re=800,P=1 and B=0.20.

Considering one main vortex flow at the lower part of a module for the V-downstream case,the center of the main vortex flow(or vortex core)at the V-tip,plane A1,is at about the middle region of the cavity.By moving to the quarter V-baffle location,plane A2,two vortex core centers move higher as well as plane A3.The upstream vortex core center is gradually vanishing as seen in plane A4.Then,the vortex flow repeats itself as it gets to the next module.This vortex flow pattern is similar for the V-upstream case,planes B1 to B5 in Fig.2(b)but different in rotating direction.

The appearance of main vortex flow leads to relatively high heat transfer because of better flow mixing between the core and wall regions.It can be concluded that the V-baffle induce four main vortex effect for the heat transfer rate and local heat transfer.

4.3.Heat transfer

Fig.4(a)and(b)displays the contour plots of temperature field in transverse planes of the V-baffle at Re=800 and B=0.20 for V-downstream and V-upstream,respectively.The figures show that there is a major change in the temperature field over the tube on both baffle cases.This means that the vortex flow s provide a significant influence on the temperature field,because it can induce better fluid mixing between the wall and the core flow regions,leading to a high temperature gradient over the heating wall.

Local Nuxcontours for the tube wall with the V-downstream and V-upstream are show n in Fig.5(a)and(b),respectively.In these figures,it appears that the higher Nuxvalues over the wall are seen in a larger area,except for a small region.The peaks are observed at the impingement areas on the baffle leading end for V-downstream and V-tip zone for V-upstream.This indicates a merit of employing the V-baffle over the smooth circular tube for enhancing heat transfer.

Fig.6 presents the variation of Nu/Nu0with Reynolds number at various B for V-downstream and V-upstream at P=1.In general,Nu/Nu0value tends to increase with the rise of Reynolds number for all cases.At B≤0.20,the Nu/Nu0for V-upstream is higher than that for V-downstream but provides lower value when B higher than 0.20.The maximum of Nu/Nu0is 17.8 for B=0.40,V-downstream and Re=2000.As seen,Nu/Nu0increases with increasing B for all Reynolds number.For the range of investigation,the use of V-baffle provides heat transfer rate higher than the smooth tube about 1-17.8.

4.4.Pressure loss

Fig.7 presents the variation of the normalized friction factor,f/f0with Reynolds number values for V-baffle.At 0.10≤B≤0.20,the f/f0slightly increases with increasing Reynolds number.How ever,above B of 0.20,friction factor significantly increase with the rise of Reynolds number.Due to the same blockage ratio of V-baffle configuration in cross sectional area,the f/f0values on both cases showed nearly values for the laminar flow region.For the range of study,the maximum f/f0is found to be about 430 for the baffles with B=0.40,Re=2000 V-upstream baffle.

4.5.Performance evaluation

The variation of thermal enhancement factor(η)for air flowing in the baffled tube with V-baffle is present in Fig.8.The enhancement factors of both the baffles tend to increase with the rise of Re values.The thermal enhancement factor for V-baffle is noticed to be maximum about 3.20 at B=0.25 and 0.20 for V-downstream and V-upstream,respectively.For the range investigated,the use of V-baffle shows that the thermal enhancement factor varies in range from 1.00 to 3.20 depending on B,Re and flow direction.

5.Conclusions

Fig.3.Details of streamlines in transverse planes for each plane(a)V-downstream and(b)V-upstream at Re=800,P=1 and B=0.20.

In this paper,laminar fully developed periodic flow and heat transfer characteristics in a circular tube fitted with 45°V-baffle elements in tandem in-line arrangement on two opposite positions have been investigated numerically.The four main vortex flows created by using 45°V-baffles help to induce impinging flow son thew all leading to drastic increase in heat transfer rate in the tested tube.As B increases,both heat transfer rate,in terms of Nusselt number ratio,and friction,in terms of friction factor ratio,increase.The V-downstream baffle gives higher heat transfer than V-upstream at B≥0.25,but the friction factor ratios on both cases provide nearly values for all B and Reynolds number values.Over the range examined,the order of heat transfer enhancement is about 1 to 17.8,for using the baffles with B=0.10-0.40.However,the heat transfer augmentation is associated with enlarged pressure loss ranging from 1 to 430 times above the smooth tube.Thermal enhancement factors for the baffles are found to be in a range of 1.00-3.20 indicating higher thermal performance over the smooth tube,depending on B,Re and flow direction.

Fig.4.Temperature contours in transverse plane for(a)V-downstream and(b)V-upstream at B=0.20,P=1 and Re=800.

Fig.5.Nu x contours for(a)V-downstream and(b)V-upstream at Re=800,P=1 and B=0.20.

Fig.6.Variation of Nu/Nu0 with Reynolds number for V-baffle.

Fig.7.Variation of f/f0 with Reynolds number for V-baffle.

Nomenclature

B flow blockage ratio,(b/D)

b baffle height,m

D hydraulic diameter of tube,m

f friction factor

Fig.8.Change of η with Reynolds number for V-baffle.

h convective heat transfer coefficient,W·m-2·K-1

k thermal conductivity,W·m-1·K-1

L cyclic length of one cell(or axial pitch length,H),m

Nu Nusselt number(=hD/k)

P pitch or spacing ratio,L/D

Pr Prandtl number(Pr= μ/Γρ,0.707 in this work)

p static pressure,Pa

Re Reynolds number(=ρUD/μ)

T temperature,K

U mean velocity in channel,m·s-1

uivelocity in xi-direction,m·s-1

α baffle inclination angle or angle of attack,(°)

Γ thermal diffusivity

η thermal enhancement factor(=(Nu/Nu0)/(f/f0)1/3)

μ dynamic viscosity,kg·s-1·m-1

ρ density,kg·m-3

Subscripts

pp pumping pow er

0 smooth channel


登录APP查看全文