肾动态显像法与双血浆法在糖尿病肾病患者肾小球滤过率测定中的价值比较

2015-12-30 07:37:25李明浩,崔时珍,玄日等
中国老年学杂志 2015年7期

肾动态显像法与双血浆法在糖尿病肾病患者肾小球滤过率测定中的价值比较

李明浩崔时珍玄日沈娟1赵国琴1

(延边大学附属医院核医学科,吉林延吉133000)

摘要〔〕目的比较肾动态显像法与双血浆法在糖尿病肾病(DN)患者肾小球滤过率(GFR)测定中的价值。方法将该院内分泌科患者68例DN患者分为早期肾病组(DN1)23例、临床肾病组(DN2)23例、尿毒症组(DN3)22例,另选取该院22例健康体检者作为健康对照组(DN0),均用肾动态显像法和双血浆法测定其GFR,分析各组两种方法所测GFR的关系。结果DN0、DN1及DN2组组内用肾动态显像法和双血浆法测定的GFR(即gGFR与tGFR)相比均无明显差异(P>0.05),DN3组gGFR与tGFR的差异具有统计学意义(P<0.05);DN0、DN1、DN2及DN3组肾动态显像法所测的GFR与双血浆法测定的GFR均呈正相关(P<0.05)。结论肾动态显像法与双血浆法均可以灵敏地发现早期DN及临床DN时GFR的变化,但肾动态显像法对于尿毒症期的患者诊断准确性差、灵敏度低,应联合病史及其他检查方法进行诊断。

关键词〔〕肾动态显像法;双血浆法;肾小球滤过率

中图分类号〔〕R445〔文献标识码〕A〔

基金项目:安徽省教育厅课题(2012SQRL074)

1安徽医科大学公共卫生学院

第一作者:李明浩(1962-),男,博士,副主任医师,主要从事核医学显像、核素治疗方面的研究。

Comparison of the value of dynamic renal scintigraphy and dual-plasma sample clearance method in measuring glomerular filtration rates of patients with diabetic nephropathy

LI Ming-Hao,CUI Shi-Zhen,XUAN Ri,etal.

Department of Nuclear Medicine, Affiliated Hospital of Yanbian University,Yanji 133000, Jilin, China

Abstract【】ObjectiveTo compare the value of dynamic renal scintigraphy and dual-plasma sample clearance method in measuring glomerular filtration rate (GFR) of patients with diabetic nephropathy.Methods68 patients were divided into early nephropathy (DN1),clinical nephropathy (DN2) and uremia groups (DN3),the number of cases in each group was 23,23 and 22 respectively;22 cases of healthy controls (DN0) were selected from the people of physical examination. The GFR of all the groups were measured both with dynamic renal scintigraphy and dual-plasma sample clearance method and analyzed.ResultsThe gGFR and tGFR of DN0, DN1 and DN2 measured by dynamic renal scintigraphy and dual-plasma sample clearance method respectively had no significant differences (P>0.05),the differences of gGFR and tGFR were significant in DN3 group(P<0.05);the correlation coefficient of gGFR and tGFR of four groups were 0.999,0.947,0.925 and 0.999,respectively,which had significant differences (P<0.05). ConclusionsBoth dynamic renal scintigraphy and dual-plasma sample clearance method could find the GFR change of early kidney disease and clinical kidney disease sensitively, but the accuracy and sensitivity of dynamic renal scintigraphy in diagnosing patients with uremia period is poor, the diagnosis of uremia should combine the medical history with other examination methods.

【Key words】Dynamic renal scintigraphy; Dual-plasma sample clearance method; Glomerular filtration rates

目前糖尿病肾病(DN)的诊断仍依靠检测尿白蛋白排泄(UAER),尚无依靠糖尿病病人肾小球滤过率(GFR)进行诊断的标准。由于UAER易受感染、运动及其他疾病的影响,故建立依靠GFR的稳定的DN诊断标准很有必要〔1〕。目前GFR的测定方法有很多,其中双血浆法已经被美国核医学会推荐为测定GFR的金标准〔2〕,并成为评价GFR 测定方法的参考标准;肾动态显像法则由于其能够测定肾血流灌注及总、分肾GFR被广泛应用于临床,但肾动态显像法在GFR测定方面的准确性仍有待确定,尤其是在不同人群中肾动态显像法对GFR的研究不多。本院……

登录APP查看全文