前门控低kV舒张末期采集联合SAFIRE技术在冠脉低剂量成像中的应用研究

2016-01-11 03:54:36肖虎,刘文亚,党军
新疆医科大学学报 2015年4期

前门控低kV舒张末期采集联合SAFIRE技术在冠脉低剂量成像中的应用研究

肖虎, 刘文亚, 党军

(新疆医科大学第一附属医院影像中心, 乌鲁木齐830054)

摘要:目的评价冠状动脉成像中前门控低电压舒张末期采集联合SAFIRE技术对射线剂量及图像质量的影响及临床应用价值。方法选取80例冠状动脉成像的患者,体质指数(BMI)<25 kg/m2,心率55~70次/min,心率波动差异<5次/min。80例患者按数字表法随机分成两组,A组40例采用前门控100 kV联合舒张末期在63%~78%的R-R采集时间窗加SAFIRE技术,B组40例采用前门控120 kV联合30%~80%的R-R采集时间窗加标准重建,Care Dose 4D设为开启,根据患者的BMI选择自动调整管电流,记录扫描中患者所受射线剂量,并对其图像质量进行评价。对两组的射线剂量和图像质量进行统计学分析。结果A组平均扫描剂量为(1.66±0.22) mSv,图像质量客观评价SNR(信噪比)=(31.16±5.65),SD(噪声)为(16.95±2.80) Hu,图像质量评分为(4.76±0.09)分;B组平均扫描剂量为(4.83±0.59) mSv,图像质量客观评价SNR=(21.44±4.46), SD为(18.95±3.17) Hu,图像质量评分为(4.66±0.25)分。A组扫描剂量与B组比较差异有统计学意义(P<0.01),平均减少约60%。A组与B组图像质量评分差异有统计学意义(P<0.05),A组与B组图像质量客观评价SNR及SD差异均有统计学意义(P<0.01);结论前门控低kV舒张末期采集联合SAFIRE技术使心率55~70次/min、波动差异<5次/min且BMI<25 kg/m2的患者在降低受照剂量的同时,图像质量能够满足临床诊断需要。

关键词:体层摄影术; X线计算机; 迭代技术; 心脏; 冠状血管; 辐射剂量

中图分类号:R445文献标识码:A

doi:10.3969/j.issn.1009-5551.2015.04.022

[收稿日期:2014-12-04]

On computed tomography low-dose coronary imaging: low tube voltage

prospective ECG-Gated scanning combined with sinogram affirmed

iterative reconstruction (SAFIRE) technique

XIAO Hu, LIU Wenya, DANG Jun

(DepartmentofRadiology,TheFirstAffiliatedHospitalofXinjiangMedicalUniversity,

Urumqi830054,China)

Abstract:ObjectiveTo evaluate the radiation dose and image quality of low tube voltage prospective ECG-gated scanning combined with SAFIRE technique. Methods80 cases were enrolled (BMI<25 kg/m2, heart rate ranged from 55 to 70 beats per minute and fluctuation of heart rate were less than 5 times per minute) and were randomly divided into 2 groups. Group A (40 patients) were used 100kV prospective ECG-gated scanning (63%-78% R-R interval) combined with SAFIRE technique; group B (40 patients) 120kV prospective ECG-gated scanning (30%-80%R-R interval) and standard reconstruction, care dose 4D were turned on. According the BMI index, the tube currents were adjusted automatically. Recorded the patients′ radiation doses, and evaluated the image quality. Independent samples group t test with SPSS software package was used for statistical analysis. ResultsGroup A, the average radiation dose was (1.66±0.22) mSv, objective evaluation of image quality: SNR=(31.16±5.65), SD(16.95±2.80) Hu, the subjective image quality scores was (4.76±0.09). Group B, the average radiation dose was (4.83±0.59) mSv,objective evaluation of image quality: SNR=(21.44±4.46), SD(18.95±3.17) Hu,the subjective image quality scores was (4.66±0.25). The radiation dose between group A and B has statistical significant (P<0.01); The subjective evaluation of image quality between group A and group B has statistically significant (P<0.05) and the objective evaluations (SNR and SD) have statistically significant (P<0.01). ConclusionLow tube voltage prospective ECG-gated scanning combined with SAFIRE technique can reduce radiation dose significantly and meet the need for diagnosis in the patients that BMI<25 kg/m2, heart rate ranged from 55 to 70 beats per minute and fluctuation of heart rate were less than 5 times per minute.

Key words: tomography; X-ray computed; Iterative reconstruction (SAFIRE) technique; heart; coronary vessels; radiation dosage

随着影像技术的飞速发展,螺旋CT冠状动脉造影(CT coronary angiography, CTCA)已经成为冠心病检查的一项重要的无创性成像手段[1]。随着CTCA普遍开展,X线辐射问题也就越来越被人们所关注,在CT检查中如何减少患者的射线剂量已成为国内外学者的研究热点[2]。Budoff等[3]认为10 mSv的CT辐射剂量就会使2 000例做过CT检查的患者中有1例患上恶性肿瘤。因此,在保证图像质量的前提下有效地降低剂量,实现“绿色成像”,便成了业界努力探索追寻的目标。目前,造成CTCA成像辐射剂量高的一个重要因素是采用回顾性门控,小螺距成像产生了较高的总体剂量,而前门控扫描模式[4]的出现大大降低了冠状动脉检查中的辐射剂量,同时成像时管电压(kV)及采集时间窗的选择也是影响辐射剂量的一个因素。Hou等[5]报道迭代技术(Iterative reconstruction technique ,SAFIRE)可使CTCA剂量降低,同时还能显著地降低图像噪声,提高信噪比。本研究主要评价前门控低kV舒张末期采集联合SAFIRE技术在冠脉低剂量成像中的应用价值。

1资料与方法

1.1一般资料选取2014年4-10月在新疆医科大学第一附属医院影像中心行冠状动脉CTCA检查的患者(冠状动脉搭桥术后患者除外)80例,BMI<25 kg/m2,心率55~70 次/min,心率波动差异<5次/min,扫描时心率平均(62±6) 次/min。男性46例(汉族24例,维吾尔族、哈萨克族22例),女性34例(汉族21例,维吾尔、哈萨克族13例),年龄38~78岁,平均(58±10)岁,身高153~180 cm,体质量47~78 kg。按数字表法随机分为两组,A组采用前门控100 kV联合舒张末期63%~78%的R-R采集时间窗加SAFIRE技术,B组采用前门控120 kV联合30%~80%的R-R采集时间窗加标准重建。排除碘造影剂过敏、严重肾功能不全(血肌酐>120 mmol/L)、心房颤动者。……

登录APP查看全文