李远
摘 要:针对某企业X射线检测装置进行辐射环境影响评价,根据屏蔽参数计算检测装置运行时周围辐射剂量率,预测在最大工况下对辐射工作人员和公众的辐射影响。评价结果表明,该X射线检测装置防护设施满足辐射防护要求,正常运行时设备周围辐射剂量率低于2.5 μSv/h限值,职业人员和公众的年有效剂量分别低于相应的法规限值和剂量约束值,企业辐射安全管理制度满足相关法规要求。
关键词:X射线检测装置 环境影响评价 辐射防护
中图分类号:X82 文献标识码:A 文章编号:1674-098X(2016)07(a)-0046-04
Environment Impact Assessment for X-ray Detection Device in an Enterprise
Li Yuan
(Suzhou Nuclear Power Research Institute, Suzhou Jiangsu,215004,China)
Abstract:For a company X-ray detection device radiation environment impact assessment, calculating the detection device operate according to the shield parameters surrounding radiation dose rate, predict the radiation impact in greatest conditions on radiation workers and the public. Evaluation results showed that the X-ray detection device protective equipment fulfil the requirements of radiation protection, professionals and the public annual effective doses were lower than the corresponding dose constraint value, enterprise radiation safety management instruction to meet regulatory requirements.
Key Words:X-ray detector; Environmental impact assessment; Radiation protection
某企業新增1台X射线检测装置,用于对企业生产的产品进行无损检测。其最大管电压为160 kV,最大管电流为3 mA,主射线方向固定朝向右侧壁。依据相关规定该X射线检测装置在正式运行前须对辐射防护设施进行评价,以确定是否满足相关法规要求。
1 项目概况
1.1 设备概况
新增1台X射线检测装置安置在厂房X-RAY室,其最大管电压为160 kV,最大管电流为3 mA,具体情况见表1。
1.2 周围环境
X-RAY室位于厂房西北侧,厂房共二层,无地下建筑。X-RAY室北侧和西侧均为工具间,南侧为化学实验室,东侧为操作车间,二层为办公区。周围50 m范围内没有居民点、学校和医院等敏感点。
2 评价标准
2.1 人员年受照剂量管理目标
职业人员年有效剂量不超过5 mSv,公众年有效剂量不超过0.25 mSv。我们取限值的1/4作为个人剂量约束值,即职业人员5 mSv/a,公众0.25 mSv/a[1]。
2.2 环境剂量率限值
X射线检测装置(铅房)四周、顶部和防护门外30 cm处,检测装置周围公众居留等区域辐射剂量率不超过2.5 μSv/h[2]。……