水中阴离子表面活性剂自动测量方法研究

2016-06-01 09:37:17黄丽华廖馨陈雅瑞
能源研究与信息 2016年1期
关键词:测量

黄丽华 廖馨 陈雅瑞

摘要:

在GB 7494—87基础上,将流动注射分析法与分光光度法相结合,利用蠕动泵及聚四氟乙烯管路进行萃取、反应和测量,将手动分析方法变成全自动的分析方法.研究表明,该方法测量阴离子表面活性剂的质量浓度范围为0~2.0 mg·L-1,最低质量浓度检出限达0.01 mg·L-1,相对标准偏差小于3.11%,加标回收率在85%~95%之间,均符合标准方法的要求.新的测量方法既保留了流动注射法快速、便捷、准确度高、稳定性好、环保等优点,同时又克服了流动注射法拖峰、管路复杂、易受气泡干扰等缺点.

关键词:

阴离子表面活性剂; 自动测量; 流动注射

中图分类号: X 832文献标志码: A

Abstract:

On the basis of the national standard of GB 7494—87,an automatic method was proposed,which combined the flow injection and the spectrophotometry and finished the extracting and measurement of the anionic surfactant in the water by peristaltic pump and PTEF.The results showed that the automatic detection method had the concentration range of 0~2.0 mg·L-1,with the detection limit of 0.01 mg·L-1,the relative standard deviation of less than 3.11%,and the recovery rate between 85% and 95%,which were consistent with the requirements of the national standard.This method not only has the same advantages as the flow injection method,such as rapid determination,convenient operation,high accuracy,good stability,good environmental protection,etc.,but also can overcome the shortcomings of flow injection method,such as law drag peak,pipeline complex,easy interference by the bubbles,and so on.

Keywords:

anionic surfactant; automatic detection; flow injection

阴离子表面活性剂会对水生生物及环境造成一定的危害和污染[1],是当前水污染的重要指标.目前国内外的测量方法主要有分光光度法[2]、荧光光度法[3]、色谱法[4]和流动注射分析法[5]等.国家标准采用化学分析法——亚甲蓝分光光度法[6].该方法具有灵敏度高、吸光度稳定、共存离子和干扰相对较小等特点,但是其操作步骤繁琐,测定时间长,而且由于采用氯仿(三氯甲烷)等有毒有机溶剂进行萃取,会对检测人员产生毒害作用.流动注射分析法是近几十年发展起来的一种新型、高效的连续流动分析技术,具有批量分析速度快、精确度和灵敏度高、试剂和样品消耗量少、操作自动化以及可与多种检测手段联用等特点[7-8],但在流动过程中测量也存在着不稳定、对实验条件要求苛刻的问题,而且与国家标准……

登录APP查看全文

猜你喜欢
测量
测量重量,测量长度……
测量的乐趣
二十四节气简易测量
日出日落的观察与测量
测量
测量水的多少……