卢佩佩,黄国虹,崔彦杰,王昌敏新疆维吾尔自治区人民医院临床检验中心,新疆乌鲁木齐 830001
强生Vitros V5600全自动生化分析仪性能评价及在急诊检验中的应用
卢佩佩,黄国虹,崔彦杰,王昌敏
新疆维吾尔自治区人民医院临床检验中心,新疆乌鲁木齐830001
目的对强生Vitros V5600全自动生化分析仪进行性能验证,以便为急诊检验提供迅速、准确的检测结果。方法参照美国临床实验室标准化委员(NCCLS)指南有关检测系统性能验证文件EP15A、EP6-A的要求对选定生化检测项目的精密度、线性范围、最大稀释倍数、方法学比对进行评价。结果21项生化指标的精密度、线性范围均符合厂商说明;经稀释后检测均值回收率均在90%<R<110%之间。结论强生Vitros V5600全自动生化分析仪的分析性能符合质量目标要求。
全自动生化分析仪;性能验证;精密度;线性范围;最大稀释倍数
[Abstract]Objective To validate the Johnson Vitros V5600 full-automatic biochemistry analyzer in order to provide rapid and accurate detection results of emergency test.Methods The precision,linearity range,maximum valid dilute double and methodology comparison of selected biochemical test items were evaluated referring to the requirement of test system performance verification file EP15A and EP6-A in the American committee of clinical laboratory standards guidance.Results The precision degree and linearity range of 21 biochemical indicators conforming to the manufacturer instructions were evaluated,and the recovery rate of detection mean value was between 90%and 110%after dilution.Conclusion The analyticity of Johnson Vitros V5600 full-automatic biochemistry analyzer can meet the quality target requirement.
[Key words]Full-automatic biochemistry analyzer;Performance validation;Precision degree;Linearity range;Maximum dilution ratio
强生Vitros V5600全自动生化分析是被称作干化学分析仪的一款全自动生化分析仪。所谓“干”是指其原理是将所需分析试剂固化于多层复合膜,当少量待检样品添加在膜上即可进行定性或定量分析。该分析仪具有抗干扰能力强、操作简便、检测迅速等特点,能够满足急诊标本检测,广泛应用于临床。该临床检验中心根据ISO15189医学实验室认可标准的要求,对该中心所拥有的强生Vitros V5600全自动生化分析进行了性能验证,现报道如下。
1.1仪器与试剂
强生Vitros V5600全自动生化分析及效期内Vitros原装配套试剂。BIO-RAD生化分析质控品(高值、低值2个浓度)。
1.2标本
就诊于该院急诊患者新鲜血清样本,无溶血、脂血、黄疸。……