宁珂

摘 要:笔者公司两台350 MW超临界机组,每台机组轴封加热器都是单级水封设计,根据以往其他机组的运行经验,目前国内设计轴加疏水水封不论是单级还是多级水封均存在运行不稳定问题,多级水封运行中易发生水封破坏现象,导致轴封冷却器的无水位运行,从而降低机组真空,严重影响机组安全、经济运行。
关键词:火电厂 凝汽式机组 轴封加热器 单级水封 疏水中断 真空
中图分类号:TM621 文献标识码:A 文章编号:1674-098X(2016)03(b)-0071-02
Abstract:our company two 350MW supercritical unit,heater per unit are single stage seal design,according to the operation experiences of other previous units, the current domestic design of shaft and hydrophobic seal whether single level or multilevel water seal are unstable operationproblem,seal failure is liable to occur in the operation of multilevel water seal,cause no waterrunning seal cooler,thereby reducing the vacuum of unit,seriously affecting the unit safety,economic operation.
Key Words:Thermal power plant;Condensing steam turbine;Shaft seal;Water seal;Heater;Single stage;Hydrophobic interrupt
1 系统简介
全厂(2×350 MW)两台供热机组,总装机容量为700 MW。机组为上海汽轮机厂C350-24.2/0.343/566/566
型超临界、一次中间再热、双缸双排汽、供热式火力发电机组,单元制运行方式。
轴封加热器是一个热交换器(见图1),串联在凝结水系统中,它的作用是将轴封来的汽气混合物用凝结水冷却,然后由装在轴封加热器顶上的风机将不凝结的蒸汽和空气排出,并维持汽封泄漏系统的压力略低于大气压力,防止从各汽封段逸出蒸汽以及抽取和凝结蒸汽。轴封加热器中凝结下来的疏水由一根U型疏水管排至凝汽器,起到回收工质的作用。
由于轴封加热器疏水是直接回收至凝汽器的,凝汽器真空远低于轴封加热器内部压力,一旦轴加疏水管段水封失去,凝汽器真空将快速下降。笔者公司两台350 MW超临界机组,每台机组轴封加热器都是单级水封设计,既要保证凝结水能顺利排出,还要能保证水封不失去而影响机组真空。
2 单级水封原理
轴封加热器在运行时处于微负压状态,压力大约在-7 kPa左右,与凝汽器真空压差约10 m水柱,按照单级水封工作原理,此水封在工作时必须产生高于10 m水柱的阻力方可保证疏水畅通又能阻止空气漏入。……