王朴 何代华 王倩 张淼



摘要:
在一定浓度的H2SO4溶液中对Ti6Al4V合金表面进行阳极氧化处理,通过改变阳极氧化处理的电压、氧化时间和电解液浓度,研究了预处理工艺参数对钛合金表面形貌、物相、润湿性及粗糙度的影响.试验结果表明:钛合金经过阳极氧化处理后,表面出现了二氧化钛(TiO2)纳米多孔结构,多孔氧化膜由锐钛矿型和金红石型TiO2组成;在0.5 mol·L-1 H2SO4溶液中,随着阳极氧化电压的增加,多孔膜的孔径逐渐增大,基体表面与模拟体液(SBF)的接触角明显降低,经120 V氧化处理的试样表面接触角由预处理前的52.8°降至16.9°左右,具有良好的润湿性;并且试样表面的粗糙度明显增加,在电压为120 V时粗糙度达到0.56 μm.在电压120 V时,随着阳极氧化时间或电解液浓度的增加,TiO2多孔膜的含量和孔径尺寸逐渐增大,试样表面的润湿性和粗糙度也不断增加,在氧化时间10 min或电解液浓度0.5 mol·L-1时达到最大,氧化时间大于10 min或电解液浓度高于0.5 mol·L-1时,试样表面出现裂纹,多孔结构被破坏.
关键词:
Ti6Al4V合金; 阳极氧化; TiO2多孔膜; 润湿性; 粗糙度
中图分类号: TG 174文献标志码: A
Abstract:
Ti6Al4V alloys were anodized in H2SO4 solution.The study was to investigate the effect of anodic oxidation parameters(the anodizing voltage,the oxidation time and the concentration of sulfuric acid) on the morphology,phase,wettability and surface roughness of Ti6Al4V substrates.The results indicated that TiO2 porous oxide films consisting of annatase and rutile phases were achieved directly on the surface of Ti6Al4V substrates after anodic oxidation.In 0.5 mol·L-1 H2SO4 solution,the pore size of the titania layer increased with the anodizing voltage increased.The contact angle on the surface of Ti6Al4V decreased obviously after anodic oxidization treatment,and the contact angle of the sample at 120 V had dropped to about 16.9 degree from 52.8 degree,which has good wettability.Moreover,the roughness increased with the increase of voltage and reached about 0.56 μm at 120 V.The content and the pore size of TiO2 porous oxide film increased gradually with the increasing of the oxidation time and the concentration of sulfuric acid.The wettability and surface roughness of substrates were also improved,which reached the best for 10 min or in 0.5 mol·L-1 H2SO4 solution.The oxide films were damaged when the oxidation time was longer than 10 min or the concentration of sulfuric acid was higher than 0.5 mol·L-1.
Keywords:
Ti6Al4V alloy; anodic oxidation; TiO2 porous film; wettability; roughness
钛及钛合金具有质轻、密度小、弹性模量低、比强度高、耐腐蚀和良好的生物相容性等优点[1-3],在骨组织工程、硬组织缺损修复、牙科以及矫形外科等医学领域得到了广泛的应用,成为人工骨植入体最为理想的生物医用金属材料[4-5].然而,钛合金属于生物惰性材料,表面活性不足,植入人体后与骨组织构成机械嵌连结构,而非化学性骨性结合.此外,通常情况下,钛合金植入材料在制备过程中会被氧化并形成一层致密、稳定的氧化膜,使其具有良好的耐蚀性能;……