《中国介入影像与治疗学》杂志2017年征订启事

2017-03-31 02:58:51
中国医学影像技术 2017年3期

《中国介入影像与治疗学》杂志2017年征订启事

《中国介入影像与治疗学》杂志创刊于2004年,是由中国科学院主管,中国科学院声学研究所主办的国家级学术期刊,主编为邹英华教授。刊号:ISSN 1672-8475,CN 11-5213/R。曾获中国精品科技期刊,现为中国科技论文统计源期刊(中国科技核心期刊)、中国科学引文数据库核心期刊、《中文核心期刊要目总览》收录期刊、WHO《西太平洋区医学索引》(WPRIM)来源期刊、荷兰《医学文摘》收录源期刊、俄罗斯《文摘杂志》收录源期刊。

《中国介入影像与治疗学》杂志以报道介入影像与治疗学、介入超声学、介入材料学、药物学与护理学等方面的临床研究、基础研究以及医、理、工结合的成果与新进展为主,是介入影像、介入治疗专业人员学习、交流的平台。

《中国介入影像与治疗学》为月刊,64页,大16开本,彩色印刷。单价:16元,全年定价192元。订户可随时向当地邮局订阅,邮发代号:80-220;亦可向编辑部直接订阅,免邮寄费(欢迎通过银行转账,附言栏请注明订阅杂志名称)。

联系电话:010-82547903 传真:010-82547903

E-mail:cjiit@mail.ioa.ac.cn 网址:www.cjiit.com

编辑部地址:北京市海淀区北四环西路21号大猷楼502室 邮编:100190

银行账户名:《中国医学影像技术》期刊社 账号:110907929010201

开户行:招商银行北京分行清华园支行 联系人:田苗

Application of MR small FOV surface coil in talar osteochondral lesions imaging

SUNYan1,SHENJunkang2,HAOYuefeng3,QINWei3,XUJixiong4*,HUDan3,LIUKefu1

(1.DepartmentofRadiology, 3.DepartmentofOrthopaedics,theAffiliatedSuzhouHospitalofNanjingMedicalUniversity,Suzhou215008,China; 2.DepartmentofRadiology,theSecondAffiliatedHospitalofSoochowUniversity,Suzhou215004,China; 4.DepartmentofRadiology,WuxiPeople'sHospital,Wuxi214023,China)

Objective To compare the accuracy rate of talar osteochondral lesions between the small field of view (FOV) surface coil MR imaging and 2D FSE proton density weighted imaging (2D-FSE-PD), 3D-SPACE sequences MR imaging with boot-shaped coil. Methods Totally 43 patients (45 ankles) underwent 3D-SPACE sequence after 2D-FSE-PD sequence scanning using the boot-shaped coil, then the PDWI sequence was scanning after the boot-shaped coil was replaced by the small FOV surface coil at 1.5T MRI. The results of the arthroscopic examinations was regarded as the standard for assessing the accuracy rate of the three methods. Results The accuracy rate of 2D-FSE-PD sequence with small FOV surface coil was 86.67% (39/45), the accuracy rate of 2D-FSE-PD sequence with boot coil was 60.00% (27/45), the accuracy rate of 3D-SPACE sequence with boot coil was 68.89% (31/45). The accuracy rate of small FOV surface coil was higher than those of boot coil used 3D-SPACE sequence (χ2=4.114,P=0.002) and boot coil used 2D-FSE-PD sequence (χ2=8.182,P<0.001). There was not significant difference between 3D-SPACE sequence using boot coil and 2D-FSE-PD sequence using boot coil (χ2=0.776,P=0.125). Conclusion Compared with the 2D-FSE-PD and 3D-SPACE sequences with boot-shaped coil, the small surface coil scanning with routine sequence can show talar osteochondral lesions better.

Magnetic resonance imaging; Radiofrequency coil; Osteochondral lesion; Talus

10.13929/j.1003-3289.201608027


登录APP查看全文