摘要:本文采用两级混凝反应沉淀法—砂滤罐过滤法处理环境监测站实验室废水,研究了对总Cr、COD和SS等的处理效果。研究结果表明把实验室废水的pH值调到8.0~9.0之间,投加聚合硫酸铁在100mg/l时,反应时间为30分钟;二级混凝反应中,在pH值调为7.5-8.5之间,投加聚合氯化铝絮凝剂的浓度为50mg/L,反应20分钟,再投加PAM为5mg/L,反应时间为10分钟;通过2级混凝反应,其总Cr、COD和SS去除率分别为100%、95%和96%。进一步通过砂滤罐过滤,出水可达标排放。
关键词:实验室废水;混凝沉淀;砂滤
中图分类号:X52 文献标识码:A 文章编号:2095-672X(2017)04-0104-02
DOI:10.16647/j.cnki.cn15-1369/X.2017.04.049
Abstract: In this paper, two-stage coagulation reaction sedimentation method and sand filter were used to treat the laboratory wastewater of environmental monitoring station. The effects of total Cr, COD and SS were studied. The results showed that the pH value of the laboratory wastewater was adjusted to 8.0 ~ 9.0, and the reaction time was 30 minutes when the polymerization of ferric sulfate was added at 100mg / l. In the secondary coagulation reaction, the pH value was adjusted to 7.5-8.5 The total concentration of Cr, COD and the total reaction time was 10 minutes. The total Cr, COD and the total reaction time was 10 min. The total reaction temperature was 50 mg / L, SS removal rates were 100%, 95% and 96%, respectively. Further through the sand filter cans, the water can reach the standard discharge.
Key words: Laboratory wastewater; Coagulation sedimentation;Sand filter
實验室废水主要有各类教育机构、研究机构、相关质检机构、质量保证和控制、医疗卫生行业的设立的各种实验室在科研、教学、工农业产品研发等活动中排放的废水以及其研究过程中弃物水等。环保部门各级监测站排放的废水就是其中的一类实验室废水[1]。实验室废水排放的水质水量均不稳定,成分非常复杂,虽然排放量小,但由于其污染成分复杂,各污染组分的浓度较高特点,极易造成环境污染事故[2,3]。目前大部分环境监测站实验室废水一般未作处理直接市政管道,其中的难降解等特殊物质和重金属元素对市政污水收集和处理设施带来一定的运行管理风险。
为了避免对环境造成污染问题,根据国家相关法律法规和相关的部门通知,有必要对环境监测站的实验室废水进行必要的的处理,达到排入市政管道的要求。目前实验室废水处理工艺主要有絮凝沉淀法[4-6]、硫化物沉淀法、氧化还原中和沉淀法[6]、活性炭吸附法[7,8]、生物膜法和活性污泥法以及它们的组合工艺。……