摘要:在经过臭氧处理后,生物膜中存在的异养菌的数量有了显著下降,而当臭氧在水中分解后,产生的氧气可以帮助生物膜的更新和恢复,确保其具备良好的净水效果。本文结合相应的试验,研究了臭氧对管道生物膜净水效能的影响,希望能够为水厂的技术更新提供一些参考。
关键词:臭氧;管道生物膜;净水效能;影响
中图分类号:P642.5 文献标识码:A 文章编号:2095-672X(2017)04-0148-02
DOI:10.16647/j.cnki.cn15-1369/X.2017.04.071
Abstract: After the ozone treatment, the number of heterotrophic bacteria present in the biofilm has decreased significantly. When the ozone is decomposed in water, the oxygen produced can help the biofilm to be renewed and restored to ensure that it has good water purification effect. In this paper, the effect of ozone on the water purification efficiency of pipeline biofilm was studied in the light of the corresponding experiment, hoping to provide some reference for the technical update of water plant.
Key words:Ozone;Pipeline biofilm;Water purification efficiency
在输水管道,尤其是长距离输水管道的运行中,为了保证输水管道的正常运行,抑制微生物的过度繁殖,一般会在水中加入液氯,改善缺氧引发的水质问题,但是这种措施会导致微生物的大量死亡,影响净水效果。对此,本文以臭氧代替液氯,就其对于管道生物膜净水效能的影响进行研究。
1 材料与方法
1.1 试验装置
结合环状生物膜反应器(BAR)对输水管道水质净化的过程进行模拟,试验装置如图所示。
在BAR内设置20个聚乙烯挂片,确保其能够围绕转子中心轴匀速旋转,转速为80r/min,模拟水流对于生物膜的剪切作用。将4台BAR并联,以R0-R3进行编号,以方便调控。在相同条件下,模拟运行65d,生物膜成熟,然后保持R0不变,向其他三个反应器中加入臭氧溶液,浓度依次为0.7mg/L,1.5mg/L,3.2mg/L。隔天对挂片生物膜上的微生物含量进行检测。
1.2 试验方法
以灭菌处理的棉签挂片挂膜面自上而下擦拭5-6次,然后将棉签放入到盛有10mL灭菌缓冲液的试管内,在超声波清洗器中震荡20min,取悬浮液进行检测。
1.3 分析方法
用浊度仪进行浊度测定,以在线溶解氧仪对DO进行测定,以TOC分析仪对TOC进行测定,对于异养菌(HPC),可以选择R2A培养基,在22℃的遮光环境下培养7d,然后进行计数[1]。……