中国与新西兰混凝土规范梁配筋量对比分析

2017-08-13 04:42:26周诚
世界家苑 2017年1期

周诚

摘 要:对中国和新西兰混凝土结构规范中的设计表达式、材料特性、荷载组合和承载力计算表达式等进行了研究,分析比较两国规范在设计参数取值和设计方法上的不同。进行了混凝土简支梁的算例分析,从而比较中国规范和新西兰规范下梁的计算配筋量差异。

关键词:新西兰规范;混凝土设计;抗弯承载力;抗剪承载力;最小配筋率

Comparison of beam reinforcement between Chinese and New Zealand code

Zhou Cheng

(CCCC-Airport Investigation and Design Institute CO.,LTD.Guangzhou 510230,China)

Abstract:The design expression,material characteristics,load combination and bearing capacity formula between Chinese and New Zealand concrete code have been studied,to compare the difference of design parameter and method.Through the instance of simply supported beam,the discrepancy of beam reinforcement quantity calculated with Chinese and New Zealand code respectively has been compared.

Keyword:New Zealand code;concrete design;calculation of flexural capacity;calculation of shear capacity;minimum reinforcement ratio

1 引言

新西兰是高度发达的国家,其混凝土结构研究一直处于国际领先水平。随着 “一带一路”建设,大洋洲地区的工程也日趋增多,大洋洲国家在工程建设中大多直接采用新西兰规范。对于混凝土结构设计,新西兰规范是NZS3101-2006:Concrete Structures Standard,而中国规范则是GB50010-2010:混凝土结构设计规范。本文以混凝土简支梁为例,通过两国规范中梁的计算公式和相关构造要求的比较,对比两国规范下混凝土梁配筋的差异。

2 设计表达式

中国规范混凝土设计采用承载能力极限状态设计,其表达式为:

(1)

式中, 为结构重要性系数,根据不同安全等级,取值0.9-1.1,地震设计状况下取1.0; 是承载能力极限状态下作用组合的效应设计值; 是结构构件的抗力设计值。

新西兰规范中混凝土的设计与中国规范类似,其表达式为:

(2)

式中, 为构件承载力设计值, 为承载力折减系数,对应不同内力工况有不同的 ; 为内力设计值。

3 材料特性

中国规范规定的混凝土强度等级由立方体抗压强度标准值fcu,k确定,共有14个等级,最低强度等级为C15,最高为C80。新西兰规范混凝土采用圆柱体抗压强度特征值fc,最低强度等级为25MPa,最高为100MPa。……

登录APP查看全文