贾库
【摘要】随着科学技术和世界经济的迅猛发展,超高层建筑的出现已逐渐成为普遍,这些巨人在防火构造设计方面是一个复杂的系统工程,因此,超高层建筑防火设计显得越来越重要。为了预防建筑火灾,人们研究制定了多种防治对策,其中搞好防火构造设计是防止火灾发生、减少火灾损失的关键环节。
【关键词】超高层;建筑;防火设计
Application of Fireproof Structure Design in Super High - rise Buildings
Jia Ku
(Zhejiang Hengxin Architectural Design Co., Ltd. Xi'an BranchXi'anShanxi710000)
【Abstract】With the rapid development of science and technology and the world economy, the emergence of super high-rise buildings has gradually become common, these giants in the fire structure design is a complex system engineering, therefore, ultra-high-rise building fire design is becoming more and more important. In order to prevent building fires, people have developed a variety of prevention and control measures, which do a good job of fire structure design is to prevent the occurrence of fire, reduce the key to the loss of fire.
【Key words】High-rise building;Fire protection design
超高層建筑的设计是一个复杂的系统工程,尤其是防火构造设计在超高层建筑建设中有着举足轻重的地位,从事建筑行业的相关人员都应对建筑设计的防火规范有充分的认识,本文从超高层火灾的危害性对防火构造设计进行了研究探讨。
1. 超高层建筑火灾的危害性
(1)火势蔓延快。
高建筑物的排气道、电缆井、楼梯间等竖向井道中,若忽略防火分隔,或方法处理不当,产生火灾时,灾情短时间内会迅速扩大。据测定,火灾刚发生时,因空气对流在水平方向造成的烟气扩散速度为0.3m/s,火势猛烈后,由于高温状态下的热对流而造成的水平方向烟气扩散速度为0.5~0.8m/s,烟气沿楼梯间或其他竖向管井扩散速度为3~4m/s。如一座高度为100m以上的超高层建筑,如无阻挡,只要半分钟即可将火势引至顶层,造成严重影响。风对超高层建筑火灾有较大的影响,测定显示,当建筑物10m高处的风速为5m/s时,在30m高处为8.7m/s,60m高处为12.3m/s,90m高处为15m/s,100m以上风速更快,由于风速增长,导致火势的蔓延,因此更加难以控制和扑灭。
(2)疏散困难。
高层建筑的特点:一是层数多,疏散到地面时间长;……