张毅


摘要: 随着近年来铁路的高速、重载发展,电气化铁路已经占据了大部分份额,由于参与列车信号控制的轨道电路设备、带动列车运行的动力设备均需要通过钢轨传导电流,所以电气化铁道干扰对信号系统的影响是不能完全避免的。目前,扼流变压器增设适配器的方式对电气化的干扰还是有比较显著的效果,本文主要结合工作原理对扼流适配器如何抗轨道电路电气化干扰进行简要分析。
Abstract: In recent years, with the development of high-speed and heavy-haul railway, the electrified railway has occupied most of the share. Since the track circuit equipment that is involved in the control of train signals and the power equipment that drives the train operation need to conduct current through the rail, the impact of electrified railway interference on the signaling system can not be completely avoided. At present, the method of adding an adapter to the choke transformer still has a significant effect on the electrification interference. In this paper, how the choke adapter against track circuit electrification interference is briefly analyzed according to the working principle.
关键词: 扼流适配器;轨道电路;电气化干扰
Key words: choke adapter;track circuit;electrification interference
中图分类号:U284.93 文献标识码:A 文章编号:1006-4311(2018)10-0223-02
电气化区段接触网供电设备属强电系统,万伏级电压、百安培级牵引电流。但信号设备均是小电流、低电压,若想在同一通道上传输不同电流、电压,其势必会对信号设备造成极大的干扰,一般来说干扰源主要包括以下几类:①受钢轨中不平衡牵引电流回流影响,轨道电路和机车信号受到传导性干扰;②受牵引网系统的感性、容性耦合影响,干扰信息传输电缆;③运动中的电力机车上的电动力系统,会对其下面的轨道电路的感性干扰;④受电力牵引系统的放射、耦合、回流地电位升等的影响,沿线及站场的固定电力电子设备会出现异常;⑤受电力机车的电、磁、电磁放射源的影响,机车上机车信号、自动停车及相应的传输线等会表现出异常。上述五类干扰源都属于电磁兼容学科范畴,从影响程度角度分析,最应该对第一类轨道电路和机车信号受不平衡牵引电流的影响加强重视。……