表面温度计示值测量结果的不确定度分析与评定

2018-04-21 13:31:56张欢郭浩苏英
品牌与标准化 2018年4期

张欢 郭浩 苏英

【摘要】 表面温度计是用于测量固体表面温度的仪器,被广泛应用于科研和生产中。本文通过建立数学模型以及对可能影响表面温度计示值测量结果的各种不确定来源的分析,对其测量结果的不确定度进行了评定。

【关键词】 表面温度计;测量结果;不确定度

【DOI编码】 10.3969/j.issn.1674-4977.2018.04.008

Uncertainty of Measurement Analysis and Evaluation of

the Surface Thermometer

ZHANG Huan, GUO Hao, SU Ying

(1. Liaoning Provincial Institute of Measurement, Shenyang 110004, China;

2. PetroChina JinXi PetroChemical Company, Huludao 125001, China)

Abstract: The surface thermometer is an instrument for measuring the surface temperature of an object. It is widely used in scientific research and production. By establishing the relative mathematical model and analyzing the sources of uncertainty which may affect the measurement results of the surface thermometer, the paper introduces the evaluation process of uncertainty.

Key words: surface thermometer;measurement result;uncertainty

表面温度计是用于测量固体表面温度的仪器,被广泛应用于航天、航空、能源、化工、纺织等科研和生产中。表面温度计由表面温度传感器和显示仪表组成。温度传感器是表面温度计的关键器件,直接决定了表面温度计的性能优劣。其测温原理是将表面温度计的温度传感器的感温元件紧密压在被测物体表面,由指示仪表来显示被测物体的表面温度(如图1)。

表面温度计校准装置主要在室温0~400℃温度范围内对表面温度计进行校准。测量方法依据JJF 1409-2013《表面温度计校准规范》,测量时采用的计量标准及其配套设备见表1。

目前知名厂家生产的经筛选后的表面温度计具有较好的重复性,可视为现有的最佳仪器。表面温度计温度范围为0~400℃,分度值分为0.1℃和1℃两种。

在校准表面温度计前,需检查表面温度源的表面热板是否存在污垢、油污,以及表面是否平整,保证表面温度计感温元件与表面温度源的表面热板得到良好接触。对表面温度计进行校准,至少选择3个校准点,可参照规程给出的参考意见选择校准点,也可根据用户需求选择校准温度点,被校准表面温度计的感温元应紧密地压在表面温度源的热板中心,待示值稳定后记下读数,重复上述步骤,每个校准点的读数不得少于3次,3次的平均值与标准器的3次平均值比较,作为表面温度计的示值误差。……