姜伟
【摘 要】通过交流电位梯度法和人体大地电容法检测,结合现场开挖验证,初步制定了适合海拉尔油田的埋地钢制管道外防腐层破损评价范围,为节约生产成本、科学指导管道维修提供技术支持。
【关键词】埋地钢制管道外防腐层检测;海拉尔油田
中图分类号: TE988.2 文献标识码: A 文章编号: 2095-2457(2018)08-0208-002
Application of Inspection Technology for External Anticorrosion Coating of Buried Steel Pipeline in Hailaer Oilfield
JIANG Wei
(Department of Planning and Design, Hailar Petroleum Exploration and Development Command, Daqing Oilfield, Hulunbuir, Inner Mongolia 021000, China)
【Abstract】Through the AC potential gradient method and human body capacitance method detection combined with on-the-spot excavation verification, the evaluation scope of the external corrosion protection layer of the buried steel pipe suitable for the Hailaer oilfield was preliminarily formulated to provide the cost saving and scientific guidance for pipeline maintenance. Technical Support.
【Key words】Buried steel pipe outer coating inspection; Hailar oil field
0 引言
随着埋地钢制管道运行年限延长,管道外防腐层难免出现老化及人为破坏情况,造成管体局部腐蚀直至穿孔,是管道安全运行的一大隐患[1-3]。对埋地管道外防腐层进行检测并评价防腐状态,寻找管道隱患位置,提出具体的维修、更换意见,成为增强管道安全运行可靠性的重要手段[4-6]。目前管道检测方法没有统一的破损评价标准,一般根据检测仪器说明书、检测环境、工作经验、开挖验证等手段综合判断[7-9]。
德苏输油管道2009年建成投产,是海拉尔油田重要的输油干线,全长85.736km,规格为Φ219×6,投产后从未检测过,为保障安全平稳运行,先后采用交流电位梯度法和人体大地电容法进行外防腐层检测,根据结果对比摸索防腐层破损评价标准。
1 检测原理[1-2]
1.1 交流地电位梯度法(ACVG)
利用电流测绘系统(PCM)与交流地电位差测量仪(A字架),通过测量土壤中交流地电位梯度的变化,查找和定位管道防腐层破损点。其原理是向管道施加一个特定的检测信号,信号沿管道传播,当管道的防腐层出现破损或补口缺陷时,以破损点为中心,在管道周围形成叠加的“点源”电场和“点源”磁场。……