纪斌

摘 要 目的:分析64排螺旋CT冠状动脉造影在诊断冠状动脉支架内再狭窄中的应用价值。方法:选取行64排螺旋CT冠状动脉造影和常规冠状动脉造影检查的冠状动脉支架置入术后患者53例(共97枚支架)。以常规冠状动脉造影结果为金标准,评估64排螺旋CT冠状动脉造影诊断冠状动脉支架内再狭窄的各项指标。结果:64排螺旋CT冠状动脉造影诊断冠状动脉支架内再狭窄的敏感性、特异性、阳性预测值、阴性预测值分别为85.7%、95.9%、66.7%和91.4%,两种方法评价支架内再狭窄差异无统计学意义(P>0.05)。结论:64排螺旋CT冠状动脉造影对评价支架内再狭窄有很好的可行性及较高的评价能力,可作为可靠筛选检查手段排除支架内再狭窄。
关键词 64排螺旋CT冠状动脉造影 常规冠状动脉造影 冠状动脉支架置入术
中图分类号:R543.31; R445.3 文献标志码:B 文章编号:1006-1533(2018)11-0049-02
Application value of 64-row spiral CT coronary angiography in the diagnosis in-stent restenosis
JI Bin
(Intervention Center, the Second Peoples Hospital of Shantou, Guangdong Shantou 515000, China)
ABSTRACT Objective: To analyze the application value of 64-row spiral CT coronary angiography in the diagnosis of in-stent restenosis. Methods: Fifty-three cases (97 stents) undergone 64-row spiral CT coronary angiography and conventional coronary angiography after intracoronary stent implantation were selected. The sensitivity, specificity, positive and negative predictive value of 64-row spiral CT coronary angiography were evaluated by taking conventional coronary angiography as a golden standard . Results: The sensitivity, specificity, positive and negative predictive value of 64-row spiral CT coronary angiography were 85.7%, 95.9%, 66.7% and 91.4%, respectively. There was no statistical significance in evaluation of in-stent restenosis by the two different methods (P>0.05). Conclusion: 64-row spiral CT coronary angiography possesses good feasibility and relatively high capacity for evaluation of in-stent restenosis and can be used as a reliable screening test to exclude in-stent restenosis.
KEy WORDS 64-row spiral CT coronary angiography; conventional coronary angiography; intracoronary stent implantation
冠狀动脉支架置入术可改善血管狭窄,重建血运,是临床上治疗冠心病的主要手段之一[1]。但支架内再狭窄仍然是一个无法回避的问题,直接影响患者的生存质量及预后[2]。因此,支架术后随访具有重要的临床意义。以往多采用导管法冠状动脉造影评价支架的通畅性,由于此种方法有创、昂贵,且具有一定危险性,患者往往不易接受,在临床上使用受到相当大的限制。近年来,随着多层螺旋CT在临床的广泛应用,CT冠状动脉造影作为一种无创性影像学检查方法日益受到重视。本文通过比较我院应用常规冠状动脉造影检查患者与64排螺旋CT冠状动脉造影检查患者的临床资料,旨在为患者寻找冠状动脉支架内再狭窄诊断寻找最适的检查方法。……p>