郑兰
【摘 要】论文根据成都亚浦耳照明电器有限公司提供的灯具产品参数,利用传统照度计算方法对苏丹上阿特巴拉水电站全厂各房间及户外区域照度进行计算,结合各房间及户外区域的功能要求以及德国监理意见对全厂照明设计进行了改进,以达到照明设计从单一的照明功能向舒适化、精细化、高效节能化发展的要求。
【Abstract】According product parameters of lamps and lanterns provided by Chengdu Oppel Lighting Company Limited, the paper uses the traditional illumination calculation method to calculate the illuminance of all rooms and outdoor areas of the factory of Upper Atbara Hydropower Station in Sudan. And combined with the functional requirements of each room and outdoor area and the German supervision opinion, the lighting design of the factory is improved, so as to meet the requirements of developing the lighting design from single lighting function to comfort, refinement, high efficiency and energy saving.
【關键词】灯具产品参数;照度计算;舒适化;精细化;高效节能
【Keywords】parameters of lamps and lanterns; illumination calculation; comfortable; refinement; high efficiency and energy saving
【中图分类号】S956.3 【文献标志码】A 【文章编号】1673-1069(2018)09-0168-02
1 引言
上阿特巴拉水电站位于在苏丹Gadaref和Kassala州交界的地方,Showak镇周边。距离首都Khartoum约460公里。到了Gadaref后再往Kassala走约70公里。电站总装机容量4*80MW、采用220kV电压等级送出。整个电站建筑包括主厂房、GIS楼、中控楼、辅助建筑楼、大坝(包括坝内廊道及房间等)。户内照明为电站建筑物内房间照明,户外照明为厂区平台、停车场,坝顶公路及厂区公路照明。
2照明系统初步设计
2.1 照度要求(业主招标文件要求)
道路和停车场 15 lx
电缆楼层、廊道、竖井、隧洞、室外建筑物 50 lx
走廊、楼梯、休息室、仓库 100 lx
机房和装配间、水轮机和发电机楼层、装置间、蓄电池室、机械车间、变压器间 250lx
控制室、电子设备室、办公室、电气/电子车间 500 lx
2.2 照明箱结构及接线设计
配电箱为封闭式结构,户内箱体采用1.5mm厚优质电解钢板,箱面采用环氧树脂静电喷涂;户外全套采用不锈钢(且配电箱设有防盗装置)。每回出线标出回路名称,户外照明箱外壳防护等级为IP65,屋内照明箱外壳防护等级为IP54。箱内配有中性母排端、接地母排端及电器安装轨道,轨道可升降调整。……