摘要:针对特高压变压器的结构,先介绍特高压变压器采用单相分体自耦变压器结构的合理性,对比有载和无载两种调压方式,分析特高压变压器调压方式及调压位置。其次对常用的2种调压补偿原理进行了介绍,给出2种补偿方式变压器各个绕组的电磁关系方程,分析2种调压补偿方式的电压调节差异。

关键词:特高压变压器、调压方式、调压位置、调压补偿原理、电磁关系

Abstract:In view of the structure of UHV (Ultra High Voltage)transformer, the rationality of single phase separate autotransformer structure is introduced. On the basis of comparision load voltage regulation with no-load voltage regulation, the voltage regulating methods and the voltage regulating position of UHV transformer are analyzed. Two principles of voltage regulating and compensation of UHV transformer are introduced. The electromagnetic relations of each winding of two kinds of different voltage regulation and compensation method of transformer are provided respectively, and the differences of the voltage regulation effect between the two kinds of voltage regulation and compensation method are analyzed and compared.

Keyword:UHV(Ultra High Voltage)transformer the voltage regulating methods the voltage regulating positionprinciple of voltage regulating and compensation The electromagnetic relations

0 引言

我国能源中心与负荷中心跨度大,这就需要可以实现远距离、大容量电力输送的特高压工程[1-2]。截至2018年5月,现在我国已经投运19条特高压工程。特高压变压器作为特高压工程主要设备之一,其绝缘性能和容量要求更高,国内外已做了大量的研究工作[1]。特高压变压器的重量和体积尺寸都很大,在设计和制造时兼顾到成本、安装、运输、可靠性等问题,目前国内所有交流特高压主变压器、特高压换流站站750 kV联络变、以及目前在建世界最高电压等级的±1100kV特高压直流工程采用的1000 kV联络变压器均采用分体布置方案,分别将主体变压器和调压补偿变压器(以下简称调补变)作为两个独立部分[2]。

本文对特高压变压器不同的调压方式和其差异进行探讨,论述了特高压变压器采用中性点无励磁调压的必要性和可行性,就调压方式来说,已有多篇文章分析了特高压变压器的调压方式,通常特高压变压器采用完全补偿方式和非完全补偿两种方式,但大部分论文均是针对非完全补偿进行电气量参数和数值分析,本文对2种调压补偿方式变压器电压调节的差别进行了分析比较,同时给出了本站特高压变压器采用完全补偿方法的变压器各个绕组的电磁关系。……