氯气校正法测定高氯水样COD瑿r的实验条件探讨

2019-10-21 16:10:14纪昳张沁雨
科技风 2019年17期

纪昳 张沁雨

摘 要:氯气校正法测定高氯水样的CODCr,其实验装置复杂,对实验条件要求比较严苛。本论文针对氯气校正法的实验条件开展相关研究,通过梯度对比实验,确定加热功率为250W~300W,氮气流速为5~10 ml/min,且在整个加热消解过程中保持稳定的加热功率和氮气流速,可保证氧化总量和氯气吸收量的相对平衡,满足对高氯废水样品的CODCr测试需求。

关键词:化学需氧量;高氯水样;氯气校正法;实验条件

Abstract:The experimental equipment of CODCr measurement of high chloride water by chlorine emendation method is complicated,and its experimental conditions are strict.This article researches on experimental conditions for chlorine emendation method.By contrast tests,we appointed the heating power as 250W~300W,and nitrogen flow as 5~10 ml/min.During the sample digestion,the heating power and nitrogen flow should remain stable,which guarantees the relative equilibrium of oxide aggregate and chlorine absorption.

Key words:CODCr;High Salinity;Chlorine Emendation Method;Experimental Conditions

化学需氧量(CODCr)反映了水体受还原性物质污染的程度,是表征地表水体、地下水体、饮用水、生活污水、工业废水污染状况,以及评价废水处理厂运行管理中的重要指标之一。[1]众所周知,氯离子是CODCr测定中的主要干扰物之一,而水质监测中常常会遇到氯离子浓度较高的废水,如化工废水、油田废水、染料生产盐析废水、沿海地区使用海水的工业废水等,其氯离子浓度有时高达10000mg/L以上[2-3]。所以,消除水体中共存的氯化物干扰问题一直是环境监测的一个重要研究方向。

2017年新出台环境保护标准HJ 828-2017中规定不适用于含氯化物浓度大于1000 mg/L(稀释后)的水中化学需氧量的测定。当氯离子含量高于1000mg/L时,先作定量稀释,使含量低于1000mg/L以下再行测定。[4]而当氯离子含量很高时,稀释带来的误差较大。[5]氯气校正法(HJ/T 70-2001)适用性相对较为广泛,适用于氯离子含量小于20000mg/L的高氯废水中CODCr的测定。但很多文献中都提到,氯气校正法由于实验装置复杂,要求实验时非常仔细,否则会带来更多误差。因此本论文将针对氯气校正法的实验条件开展相关研究,探讨影响氯气校正法测定准确性的因素,以期细化对高氯水样CODCr的监测工作。……

登录APP查看全文