李美增 谢贤林 陆宗达



摘 要:接地刀闸机构简单,操作方便,被广泛应用在6.6kV及以上配电装置母线侧、断路器两侧、线路隔离开关的线路侧。而在方家山机组,在高压开关柜、500kVGIS开关站进线、500kVGIS开关站的三路出线等都应用了大量的接地刀。文章主要针对方家山主变高压侧增设的一组手动接地开关0GEW139JE以及500kVGIS开关站出线上的快速接地刀的应用进行分析,学习如何根据电站实际需要充分考虑设备运行安全和检修需要,并结合系统安全、可靠运行的需要,具体情况具体分析,选用合适的不同类型的接地刀闸,并且配合不同类型的联锁措施,保证地刀和相应隔离开关的连锁,确保设备检修和故障情况下人员与设备的安全,只有这样才能发挥接地开关的功能作用。
关键词:检修接地刀;快速接地刀;联锁设置
中图分类号:TM564 文献标志码:A 文章编号:2095-2945(2020)10-0170-02
Abstract: The grounding knife gate has the advantages of simple mechanism and convenient operation, so it is widely used in the bus side of the distribution equipment above 6.6kV, both sides of the circuit breaker and the line side of the line isolation switch. In Fangjiashan unit, a large number of grounding knives are used in the high voltage switchgear, the incoming line of 500kVGIS switch station and the three-way outlet of 500kVGIS switch station. This paper mainly analyzes the application of a group of manual grounding switches 0GEW139JE added on the high voltage side of Fangjiashan main transformer and the fast grounding knife on the outlet of 500kVGIS switch station, and learns how to fully consider the needs of equipment operation safety and maintenance according to the actual needs of the power station, and how to select different types of grounding switches according to the needs of safe and reliable operation of the system, and cooperate with different types of interlocking measures to ensure the linkage of the ground knife and the corresponding isolation switch, to ensure the safety of personnel and equipment in the case of equipment maintenance and fault. Only in this way can we play the function of grounding switch.
Keywords: maintenance grounding knife; fast grounding knife; interlock setting
1 引言
接地開关作为检修时的安全保护装置,其配置位置由系统主线确定。接地开关的壳体与GIS壳体之间设有绝缘隔板,可用于主回路电阻的测量、断路器触头接触的检测等。接地开关根据技术规范的要求由一台手动或气动或电动操动机构操作。为了防止误操作关合到带电主回路上,接地开关应与其相关的隔离开关、接地开关和断路器联锁,以此来保证检修时设备的安全接地功能,保障设备和检修人员的安全。发电厂的用电等级覆盖了高低压等不同电压等级,对接地开关的作用及使用情况各有不同,除普通接地刀外,方家山主变高压侧就特意要求增设一组接地开关以满足实际情况的需要。……