吴童 来永斌 王龙



摘 要
本文通过数值模拟的方法研究平顶屋光伏板周围的风场结构。结果表明,在屋顶前缘产生气流分离现象,并产生一定范围的负压区域,其中的光伏板表面压力梯度均为负压。在180°风角下,光伏阵列被屋顶涡流包裹,并在光伏板的阻挡作用下,屋顶涡流发生分离,此外,第一排光伏板下表面前缘也产生了一个涡。
关键词
平顶屋;光伏阵列;风载荷
中图分类号: TM615 文献标识码: A
DOI:10.19694/j.cnki.issn2095-2457.2020.15.065
Abstract
In this paper,the wind field structure around flat roof photovoltaic panels is studied by numerical simulation.The results show that there is an air flow separation at the front edge of the roof,and a certain range of negative pressure area is generated,in which the pressure gradient on the surface of photovoltaic panels is negative pressure.At 180° wind angle,the photovoltaic array is wrapped by the roof vortex,and the roof vortex is separated under the blocking effect of the photovoltaic panel.In addition, the leading edge of the lower surface of the first row of photovoltaic panels also generates a vortex.
Key Words
Flat roofs;Photovoltaic arrays;Wind load
0 前言
光伏电站的建立,对地形、气候等因素要求较高。在解决光伏电站适应性问题的过程中,低矮建筑屋顶建设光伏电站也是一个可行方案。由于屋顶的风場结构复杂,研究屋顶光伏板结构载荷中的风载荷具有重要意义。
Ayodeji Abiola-Ogedengbe[1]等,研究发现,在偏风角下,光伏板表面压力是不对称的,并且板间间隙对光伏组件的表面压力有明显的影响。Alexander Bronkhorst[2]等人对屋顶光伏阵列进行风洞试验和计算流体力学进行比较,结果表明,总体压力分布具有较好的预测效果。Jingxue Wang[3]等人研究建筑物参数对屋顶光伏板风载荷的影响,结果表明,建筑物参数的变化对屋顶光伏板的风载荷有很大影响。随着CFD数值模拟技术的发展,其对建筑物表面及周围的流场预测越发接近现实,在工程应用范围内可获得具有合理精度的解[4],这为建筑物风载荷研究分析提供了可靠的手段。
本研究采用CFD数值模拟分析平顶屋屋顶光伏板在风向角下周围的流场、表面压力的变化,以研究屋顶光伏阵列与地面光伏阵列的差异性,从而为屋顶光伏板的研究提供参考。……