高研芬 郑淏 王斐

摘 要:目的:建立利用核壳型色谱柱和高效液相色谱串联质谱法快速测定环境水样中克百威的分析方法。方法:水样经过0.45μm微孔滤膜过滤,采用核壳型Waters Cortecs C18色谱柱(100×2.1mm,2.7μm)分离,以甲醇-水(0.1%甲酸)为流动相,在加热电喷雾电离源、正离子模式下,采用选择反应监测模式采集数据。结果:在0.2~100μg/L的范围内线性关系良好,相关系数>0.999。方法的检出限为0.02μg/L。在2.0和20.0μg/L2个添加水平下,方法的回收率在84.9%~89.8%,相对标准偏差在1.3%~3.3%。结论:该方法简单、快速、灵敏度高,适合于环境水样中克百威的测定。
关键词:克百威;核壳型填料;水样;高效液相色谱串联质谱
中图分类号 X832文献标识码 A文章编号 1007-7731(2020)14-0142-02
Abstract: Purpose:A rapid method for the determination of carbofuran inenvironmentalwaters using a core-shell column and high performance liquid chromatography-tandem mass spectrometry was established. Method:The water samples filtered with 0.45μ mmillipore filter were analyzed by core-shellWaters Cortecs C18 column (100×2.1mm, 2.7μm) using methanol and 0.1% (v/v) formic acid aqueous solution as mobile phases. The analytes were detected using a heated electrospary ionization (HESI) source under the SRM mode. Result: The calibration curve for carbofuran was linear in the range of 0.2~10.0μg/L, with correlation coefficient greater than 0.999. The limit of detection was 0.02μg/L.The recoveries ranged from 86.0% to 94.7% and the relative standarddeviations ( RSDs) ranged from 1.4% to 2.9% when spiked levels were at 2.0, and 20.0μg/L. Conclusion:This method can be applied to the determination of carbofuranin environmental water samples with the advantage of simplicity, rapidity, and high sensitivity.
Key words: Carbofuran; Core-shell stationary phase; Water samples; High performance liquid chromatography-tandem mass spectrometry (LC-MS/MS)
克百威,也称呋喃丹,是一种氨基甲酸酯农药,为高毒杀虫剂,广泛使用于农业生产中。据研究,25℃时克百威在水中溶解度为0.7g/L,溶解度较大,易污染土壤和水体,具有潜在的污染环境水体的可能。当前,克百威的测定方法有气相色谱法,液相色谱-柱后衍生法[1-2]、液相色谱串联质谱法[3-4]。由于克百威热稳定性差,遇高温易分解,因此不宜用气相色谱分析。液相色谱-柱后衍生法需要额外的衍生装置,前处理过程也比较花费时间,精密度和准确度都较差。而液相色谱串联质谱法具有定性准确、灵敏度高的优点,适合于水体中克百威的测定。
受到系统压力的限制,高效液相色谱多使用直径为5μm或3μm的全多孔硅胶填料,不能通过使用更小粒径的填料进来一步提高柱效。而核壳型填料[5-6]具有特殊的结构,由1个实心核和包裹实心核的多孔壳层组成。与……