李欣 刘秀清 袁松 霍艳 杨丽 李玉昶 李寒冰



摘 要:建立了通过用钠度计测定裂解用液化石油气吸收水中钠离子含量的方法,间接计算出液化气中残留的钠离子含量,同时用pH计测出吸收水的pH值,由此快速判定液化气携带碱的情况[1]。该方法操作简便,线性范围宽,最小检出限为0.4 μg·L-1,比UOP699原子吸收分光光度法线性范围宽百倍,分析成本低,精度高,分析时间短。
关 键 词:钠含量;液化气;钠离子选择电极
中图分类号:O657 文献标识码:A 文章编号: 1671-0460(2020)07-1556-04
Measuring Method of Sodium Content in Liquefied Petroleum Gas
LI Xin1, LIU Xiu-qing1, YUAN Song2, HUO Yan1, YANG Li1, LI Yu-chang1, LI Hang-bing1
(1. Olefin Plant of Fushun Petrochemical Company, Fushun Liaoning 113004, China;
2. Fushun Technology Innovation Research Institute, Fushun Liaoning 113001, China)
Abstract: The test method of sodium content in light petroleum gas by sodium ion meter was established, and sodium content was calculated through determining Na+ content in washing water of LPG. At the same time, the pH of the water was determined by pH meter, as a result, the pH of LPG sample was confirmed. Using this method, the sample pretreatment process is simple, the determination result is accurate, the detection limit is 0.4 μg·L-1, the linear range is wide, the analysis time is shorter than UOP 699 ,and the analysis cost is also lower.
Key words: Sodium content; Liquefied petroleum gas; Sodium ion selective electrode
乙烯装置生产乙烯和丙烯的传统工艺路线为石脑油蒸汽裂解,为了降低成本提高效益,以液化石油气(LPG)代替石脑油的新工艺已经越来越多地应用到生产中。而炼厂生产的液化石油气是采用20%的碱(氢氧化钠)及纤维液膜工艺脱硫醇、硫醚等含硫物质的,如果该工艺出现问题,液化气中可能会携带少量的碱,而碱的存在对乙烯裂解炉管及其后续生产的平稳运行产生极大的影响,会导致裂解效率降低,同时裂解气中一氧化碳、二氧化碳超标,严重时破坏碱洗系统平衡,导致乙烯、丙烯中一氧化碳、二氧化碳不合格。通常情况下,乙烯裂解用液化石油气关注的是烯烃、碳五及碳五以上组分和硫含量,忽略了酸碱性的问题。2018年 6月16日烯烃厂发现了LPG中带碱的现象,虽然发现的比较及时但对裂解炉也造成了一定的损害。为此,建立了快速检测裂解液化石油气中碱的含量的方法并定期进行监测,以杜绝此类事件的再次发生。……