张健新 张标 丁传林



摘要:為减小配置HRB600钢筋梁柱边节点的梁筋粘结退化,设计钢纤维整体增强或局部增强的梁柱边节点,进行两个配置HRB600/HRB400钢筋混凝土梁柱边节点和2个配置HRB600高强钢筋的钢纤维整体增强或局部增强的混凝土梁柱边节点的低周往复荷载试验,得到试件的破坏形态和滞回曲线,对比分析边节点的耗能能力、延性性能、核心区剪切变形和梁筋粘结退化。结果表明:往复荷载下HRB600钢筋混凝土节点具有较高的承载能力、耗能能力和延性性能,但HRB600钢筋与普通混凝土粘结退化过快;钢纤维整体增强或局部增强混凝土的措施可以减缓HRB600梁筋粘结退化,改善边节点的破坏形态,减小核心区的剪切变形,提高耗能能力;钢纤维整体增强的梁柱边节点具有更高的延性性能和耗能能力,其HRB600梁筋粘结退化更为缓慢。
关键词:梁柱边节点;HRB600钢筋;钢纤维混凝土;抗震性能
中图分类号:TU375.4 文献标志码:A 文章编号:20966717(2020)04010508
收稿日期:20191014
基金项目:河北省自然科学基金(E2018202290、E2019202064);河北省高层次人才资助项目(B2017003003)
作者简介:张健新(1986 ),女,博士,主要从事结构抗震研究,Email: zhangjianxin505@126.com。
Received:20191014
Foundation items:Natural Science Foundation of Hebei Province (No. E2018202290,E2019202064); HighLevel Talents Project of Hebei Province (B2017003003)
Author brief:Zhang Jianxin (1986 ), PhD, main research interest: structure seismic, Email: zhangjianxin505@126.com.
Experimental analysis on seismic behavior of steel fiber concrete beamcolumn exterior joints with HRB600 reinforcement bars
Zhang Jianxin, Zhang Biao, Ding Chuanlin
(School of Civil and Transportation Engineering, Hebei University of Technology, Tianjin 300401, P.R. China)
Abstract: In order to reduce the bond degradation of beam reinforcement bars in beamcolumn exterior joints with HRB600 reinforcement bars, the beamcolumn exterior joints with overall or local steel fiber concrete were designed. The lowcycle loading tests were carried out on two ordinary concrete beamcolumn exterior joint with HRB600/HRB400 reinforcement bars, and two steel fiber concrete beamcolumn exterior joints with overall or local steel fiber concrete and HRB600 reinforcement bars. The failure modes, hysteresis curves, energy dissipation, ductility, shear deformation in the core zone and bond degradation of beam reinforcement bars were analyzed. The research results showed that the joints with HRB600 reinforcement bars exhibited higher bearing capacity, energy dissipation capacity and ductility under lowcycle loading, but the bond degradation between HRB600 reinforcement bar and ordinary concrete degraded too quickly. The exterior joint reinforced by overall or local steel fiber concrete exhibited slower bond degradation of HRB600 beam reinforcement bars, slighter failure mode, smaller shear deformation in the joint core area, and larger energy dissipation capacity. The beamcolumn exterior joint with overall steel fiber concrete had higher ductility and energy dissipation capacity compared with the beamcolumn exterior joint with local steel fiber concrete, and the bond degradation of HRB600 beam bars was slower.
Keywords:exterior beamcolumn joint; HRB600 reinforcement bars; steel fiber concrete; seismic behavior
随着高性能结构的发展,普通钢筋混凝土结构已经很难满足现代化结构的要求,许多学者关注高强钢筋高性能混凝土结构的研究[12]。作为混凝土结构关键部位的梁柱节点,其抗震需求较高,因此,需要配置足够数量的钢筋,由此导致节点区域钢筋密集。特别是梁柱边节点,梁纵筋在节点区域弯折锚固致使节点区域钢筋密集,浇筑混凝土容易拥堵而不容易密实[34]。……