左宁心 辛继群 强小波



摘 要:根据1913t/h锅炉引风机冷却风机的安装特点,针对其检修困难、易腐蚀、振动大等问题,利用引风机入口负压代替轴承冷却风机进行冷却系统优化,对优化方案的可行性、经济性进行了分析。实际应用达到了保障系统安全和节能的目的,是锅炉引风机轴承冷却系统优化和改造的成功实例。为同类机组提供了有益的参考。
关键词:锅炉;引风机;轴承冷却风机;节能
中图分类号:TM621 文献标志码:A 文章编号:2095-2945(2020)30-0165-02
Abstract: According to the installation state of a induced draft fan cooling fan in the 1913t/h boiler, the cooling system was improved through a replacement of the bearing cooling fan by applying the inlet negative pressure of the induced draft fan, in order to deal with the common obstacles (e.g., maintenance difficulties, corrosion, and vibration). The feasibility and economy of the optimal case was analyzed. The practical application of the optimal case, which improved the bearing cooling system of boiler induced draft fan and thus enhanced its performance, succeeded in satisfying the demand for system safety and energy conservation, and therefore, provided a useful reference for similar systems.
Keywords: boiler; induced draft fan; bearing cooling fan; energy saving
引言
电站引风机轴承冷却系统一般采用循环油系统对轴承箱和液压控制部分内部进行润滑及冷却,同时利用冷却风机对以上设备外部进行冷却,同时保护轴承箱上的温度及振动测点不被高温烟气损坏或被腐蚀,并且对油管路有一定的保护作用。
冷却风机就地吸风,以上海鼓风机厂双级动叶可调式轴流风机为例,每台引风机液压控制部分和轴承箱各配备两台(一备一用)4-72-11离心式风机,对其进行冷却。而现场实际冷却风机的性能优劣和运行稳定与否,直接影响风机运行的安全性、经济型以及机组的运行情况。
1 概况
长安益阳发电有限公司锅炉型号为HG1913/25.4-PM8,超临界参数变压运行直流炉,单炉膛、一次再热、平衡通风、露天布置、固态排渣、全钢构架、全悬吊结构π型锅炉,燃烧方式采用前后墙对冲燃烧。
风烟系统采用2台一次风机、2台送风机和2台引风机平衡通风。其中引风机为上海鼓风机厂有限公司出产的双级动叶可调式轴流风机。……