反渗透膜长周期运行离线清洗方法探究及浅析

2021-01-15 00:46:10袁国光关赛赛李虹
科技创新导报 2021年23期

袁国光 关赛赛 李虹

摘要:本文通过对污染物,脱盐率,来水水质、清洗方法等原因进行了剖析,通过数据分析和实际清洗使用效果,总结提出了来水水源变化下,反渗透系统膜经过长周期运行后的离线清洗方案和步骤。因此,来水污染物精准分析及清洗方法的改进,脱盐水的脱盐率和回收率得到了明显提高,并且延长了清洗周期,以期为相关行业人员提供参考。

关键词:反渗透;脱盐率;清洗剂;污染物;余氯;生石灰

Abstract: Through the analysis of pollutants, desalting rate, incoming water quality, cleaning methods and other reasons, through data analysis and actual cleaning effect, the off-line cleaning scheme and steps of reverse osmosis system membrane after long-term operation under the change of incoming water source are summarized and put forward. Therefore, the accurate analysis of incoming water pollutants and the improvement of cleaning methods, the desalination rate and recovery rate of desalted water have been significantly improved, and the cleaning cycle is prolonged, in order to provide reference for relevant industry personnel.

Key Words: Reverse osmosis; Desalination rate; Cleaning agent; Contaminants; Residual chlorine; Quick lime

河鋼邯钢能源中心第七软水脱盐水站反渗透系统经过了近8年长周期运行,而且近几年环保对钢厂外排水质要求不断提高,水源水质复杂,虽然污水处理厂对生产做了相应调整,但部分污染物质是去除不掉的。七软水站反渗透膜脱盐率下降明显,单套产水电导率升高,离线清洗效果不明显和运行周期短的情况,这样对反渗透的出水水质造成了严重影响。各种污染物会对反渗透膜造成严重后果。因此,我们要讨论的是:因来水水源变化给长周期运行的反渗透膜造成影响的浅析及反渗透膜离线清洗的方法探究。

1 反渗透系统概述

河钢邯钢能源中心第七软水脱盐水站2013年投产,有7套一级反渗透装置。1号到3号每套膜支共计17根;排列11:6;每套6支装。生产商美国DOW公司型号BW30-400FR;4号到7号每套膜支共计28根;排列18:11。每套6支装。一级反渗透系统回收率:75%,脱盐率:98%。二级反渗透共计2套。每套膜支共计13根;排列9:4;每套6支装。在离线清洗反渗透膜过程中,发现膜表面有一层白色物质。……

登录APP查看全文