对射式可燃气体检测报警器的安装使用及测试方法探讨

2021-07-09 17:00:18张宁孙景斌李淼
品牌与标准化 2021年2期
关键词:工作原理

张宁 孙景斌 李淼

【摘要】 可燃气体报警器广泛应用于冶金、燃气、化工、石油等行业,用于检测室内外危险场所的泄露情況,是保证人身安全和安全生产不可或缺的仪器。本文首先介绍了不常见的特殊型报警器—对射式可燃气体报警器的工作原理,详细分析了对射式可燃气体报警器的使用与检测,为进一步研究提供依据。

【关键词】 对射式可燃气体报警器;工作原理;测试方法

【DOI编码】 10.3969/j.issn.1674-4977.2021.02.036

Discussion on Installation, Use and Test Method of Infrared Hydrocarbon Gas Detector Open Path Eclipse

ZHANG Ning1,SUN Jing-bin2,LI Miao2

(1.Liaoning Institute of Measurement,Shenyang 110004,China;

2.Fushun measurement and Testing Institute,Fushun 113006,China)

Abstract: Combustible gas alarm is widely used in metallurgy,gas,chemical,petroleum and other industries. It is used to detect the leakage of indoor and outdoor dangerous places. It is an indispensable instrument to ensure personal safety and production safety. This paper introduces the unusual special combustible gas alarm-infrared hydrocarbon gas detector open path eclipse,it is also introduces the working principle of the alarm,analyzes its use and detection in detail,and provides the basis for further research.

Key words: infrared hydrocarbon gas detector open path eclipse;working principle;test method

石化公司的油气储存车间,存在大量储存罐。由于场地比较大空旷,所以安装了大量对射式可燃气体检测报警器来监测环境中的可燃气体浓度。对射式可燃气体检测报警器由发射器和接收器两部分组成,每对探测器通过报警中继器相连接。发射器和接收器按轴线安装拉开一定距离。形成一个监视区域,当被监视区域有可燃气体泄露时,发射器发出的红外光通过检测区域到达接收器并被其接收。接收器不断采集接收端红外光光强的变化情况即监测区域有可燃气体的浓度情况及整体光强衰减情况,并把采集数据以数字信号的形式通过传输线传给报警中继器。报警中继器通过对接收到的数字信号进行分析判断,来确定探测器的工作状态,进行可燃气体浓度显示、报警并输出报警信号。

目前国内尚无开放对射式可燃气体检测报警器的相关计量检定规程或校准规范,本文在结合该类设备测量原理基础和实践的基础上,参照JJG 693-2011《可燃气体检测报警器鉴定规程》初步探索了对射式可燃气体检测报警器的测试方法。……