李隆锋 陈浩



DOI:10.16661/j.cnki.1672-3791.2103-5042-2206
摘 要:某发电公司660 MW汽轮发电机组三抽温度随着机组启停逐步升高,最高达到508 ℃,严重影响了机组的安全。该文主要从机组结构出发,对三抽温度升高的原因进行分析,制定临时运行措施,保证运行期间机组的安全性,同时结合高中压缸检修时,对缺陷进行了处理,最终达到了预期的效果,保证了机组的经济性。该问题的处理和解决可为其他同类型电厂提供借鉴。
关键词:电厂 660 MW 三抽 安全性
中图分类号:TM621 文献标识码:A文章编号:1672-3791(2021)03(b)-0036-04
Cause Analysis and Treatment of High Temperature of Third Extraction of Steam Turbine in a Power Plant
LI Longfeng CHEN Hao
(Zhejiang Zheneng Leqing Power Generation Co., Ltd., Wenzhou, Zhejiang Province, 320609 China)
Abstract: With the start-up and shut-down of 660 MW steam turbine generator unit, the temperature of the third extraction of 660 MW steam turbine generator unit in a power generation company gradually increases, and the maximum temperature reaches 508 ℃, which seriously affects the safety of the unit. Starting from the structure of the unit, this paper analyzes the reasons for the temperature rise of the third extraction, formulates temporary operation measures to ensure the safety of the unit during operation, and at the same time, combined with the maintenance of the high and medium pressure cylinder, it deals with the defects, and finally achieves the expected effect and ensures the economy of the unit. The treatment and solution of this problem can provide reference for other similar power plants.
Key Words: Power plant; 660 MW; Third extraction; Safety
某发电公司#2机组660 MW超临界燃煤发电机组,自2018年3月份开始,每次停机后再开机时,三抽温度均有不同程度的上升,每次约上升10 ℃,至2020年机组停运检修前,#1机的三抽温度最高值达508 ℃,与设计值偏差较大。三抽温度的升高,对机组的安全性和经济性产生了很大的影响。该文主要阐述了三抽温度异常的原因分析,并进行了相关处理。
1 設备概况
某发电公司#2机组600 MW超临界燃煤发电机组于2008年9月10日投产发电。汽轮机系上海汽轮机有限公司引进美国西屋技术设计制造,是超临界、一次中间再热、单轴、三缸四排汽、反动凝汽式汽轮机,型号为N600-24.2/566/566,机组铭牌功率为600 MW。公司于2015年对汽轮机的高中低压缸通流部分进行了优化改造,并配套实施了锅炉、发电机、主变等扩容改造项目,将机组的额定出力由600 MW提高至660 MW。通流改造前后THA工况下三级抽汽温度及压力的变化情况见表1。
2 原因及措施
从2015年通流改造后机组运行期间的三抽温度、高中压缸缸胀、差胀等相关趋势图来看,可以发现自2018年起,每次开停机都会引起三抽温度的变化,同时高中压缸缸胀、差胀也相应均有上升。……