吴小波 李生勇 焦森林 郑之寿



DOI:10.16660/j.cnki.1674-098x.2011-5640-8257
摘 要:本文介绍了过滤精度2μm和5μm,新研发的以316L不锈钢纤维毡为滤材的核电厂水过滤器滤芯综合试验性能并和相应性能的目标值进行了对比。通过比较新研发滤芯的结构完整性验证和初始冒泡点、压降流量特性、过滤效率和纳污容量等试验项目实测值和目标值,对新研发滤芯的结构、工艺等进行持续改进,不仅使得新研发滤芯各项性能指标实测值满足目标值要求,而且部分性能指标实测值优于目标值。
关键词:滤芯 综合性能 试验 目标值
中图分类号:TM623 文献标识码:A 文章编号:1674-098X(2021)01(c)-0071-04
Performance Test of High Precision Water Filter Element in Newly Developed Nuclear Power Plant
WU Xiaobo1 LI Shengyong2 JIAO Senlin1 ZHENG Zhishou1
(1.Hualong Nuclear Power Technology Co., Ltd., Beijing, 100036 China;2.AT&M Environmental Engineering Technology Co., Ltd., Beijing, 100081 China)
Abstract: This paper introduces the comprehensive test performance of newly developed water filter element used in nuclear power plant, the filter element is made of 316L stainless steel fiber felt with filtering precision of 2μm and 5μm,meanwhile, the measured value and the target value are compared. By comparing the measured and target values of initial bubble point, pressure drop flow characteristics, filtering efficiency and pollution carrying capacity, etc. Continuously improve the structure and process of the newly developed water filter element, not only the measured values of each performance index of the filter element meet the requirements of the target value, but also the measured values of some performance indexes are better than the target values.
Key Words: Filter element; Comprehensive performance; Test; Target value
當前核电厂核岛辅助系统中设置的水过滤器滤芯的材质主要为玻璃纤维,玻璃纤维材质的水过滤器滤芯在核电厂长期使用过程中存在着纤维脱落对水质造成二次污染以及可溶硅的析出量可能累计到一个相当高的量,造成一回路水质持续恶化,影响到核岛主设备的安全稳定运行。为此项目组经过仔细研究对比,发现316L不锈钢纤维毡作为核电高精度滤芯的滤材有强度高以及长时间浸泡在一回路模拟溶液中未检测到析出的硅元素等优点。下文介绍了此次新研发,以316L不锈钢纤维毡为滤材,过滤精度2μm和5μm的核电厂水过滤器滤芯综合试验性能并和相应性能的目标值进行了对比。滤芯综合性能的目标值来源于标准、规范以及国外进口的同精度、同尺寸、滤芯材质为玻璃纤维的试验实测值,试验项目参照NB/T 20486-2018的要求,进行了滤芯结构完整性验证和初始冒泡点的确定、压降流量特性等七项性能试验。……