高层建筑防雷检测重点问题探讨

2012-04-10 04:59:40谢思茜洪敏
城市建设理论研究 2012年6期
关键词:规范检测

谢思茜 洪敏

摘要:随着现代社会经济的迅猛发展,高楼大厦的平地拔起,高层建筑的防雷检测工作显得越来越重要,如何规范化的做好高层建筑防雷检测服务工作事关民生。本文首先对高层建筑物的防雷安全检测要点进行汇总分析,明确高层建筑物防雷检测应该关注的重点部位,然后对高层建筑物防雷设计常见问题进行探讨,提出高层建筑防雷检测的关键技术以及进一步加强和规范防雷定期检测工作,确保建筑物的防雷安全。

关 键 词: 高层建筑防雷接地检测

中图分类号: TU97 文献标识码:A 文章编号:

Abstract: With the development of modern social economy rapid development, the flat out many-storied buildings, high-rise building lightning detection work becomes more and more important, how to standardize well of high-rise building lightning protection testing services for people's livelihood. This paper first on high-rise building lightning safety testing of pooled analysis of high-rise buildings, clear mine detection should focus position, and then on high-rise building lightning protection design of common problem undertakes discussing, put forward the key technology of high rise building lightning detection and further strengthen and standardize the lightning periodic testing work, ensure safety of lightning protection of buildings.

Key words:Tall building; Lightning protection; Grounding detection.

1高层建筑物的防雷安全检测要点

(1)外部防雷装置检测内容包括:引下线的间距、引下线、柱筋的利用系数、焊接质量、搭接长度。接闪器是由避雷带、避雷网、避雷针组成,其接闪器布设是否符合防雷类别的要求。均压环的检测:从在一类防雷30m起(二类防雷45m)的高层建筑物,每两层做一次均压环,检查30米(45米)外墙的门窗、金属栏杆及金属饰品是否与防雷装置连接。

(2)内部防雷装置检测内容包括:电源系统应检查总配电及消防控制系统、精密设备是否按照防雷技术要求安装SPD、各楼层配电箱;安装的SPD的安装位置、技术参数、数量是否符合防雷技术规范要求。信号系统应检测计算机监控系统、网络系统、火灾报警控制系统是否按照规范安装SPD,其规格型号等是否符合要求。

(3)弱电机房接地装置应检测:等电位连接和综合布线的电子信息线缆主干线的金属线槽是否敷设在电气竖井内。……