杨宝辉
摘要:城镇污水处理厂进水的可生化性对污水处理厂的设计具有决定性意义。论文选取某市监测数据比较完整的四家城镇污水处理厂,以2006年~2008年进出水水质指标监测数据为分析对象,首先采用综合评价方法对某市城镇污水处理厂进出水可生化性进行分析。通过对比可生化性标准,得出该市城镇污水处理厂进水的可生化性良好,适合采用二级生化处理工艺进行处理。与进水可生化性不同,城镇污水处理厂出水可生化性较差,继续采用生化处理方法不适宜。
关键词:城镇污水处理厂 综合评价方法 可生化性线性关系
Abstract: the urban sewage treatment plant of water to the sewage treatment plant of biochemical design is of decisive significance. Selected papers on the monitoring data of relatively complete four urban wastewater treatment plant to 2006 ~ 2008 years in and out of the water quality monitoring data for analysis object index, first by the integrated evaluation method to some city town sewage treatment plant in and out of the water can biochemical sex for analysis. By comparison, biochemical sex standard, draw the city town of sewage treatment plant water can be biochemical good sex, suitable for the level 2 biochemical process for processing. And the water can be different biochemical sex, towns sewage treatment plants can be poor water biochemical sex, continue to the biochemical treatment methods are not suitable for.
Key words: the urban sewage treatment plant comprehensive evaluation method of linear relationship between the biochemical
中图分类号:[R123.3]文献标识码:A 文章编号:
1、前言
城镇污水处理厂进水的可生化性对污水处理厂的设计具有决定性意义。废水的可生化性是影响废水生物处理效果的重要因素,确定处理对象废水的可生化性,对于废水处理方法的选择、确定生化处理工段进水量、有机负荷等重要工艺参数具有重要的意义。
收集了某市四家污水处理厂2006年-2008年连续监测的进水水质指标BOD5、CODcr,本文利用积累的三年翔实的实测数据,采用综合评价方法,对该市处理规模较大的四家污水处理厂的可生化性进行分析。
2、可生化性评价方法及依据
BOD5与CODcr的比值是鉴定废水好氧可生化性的一个重要指标。我国污水行业普遍认为:BOD5/CODcr≥45%,可生化性良好;BOD5/CODcr≥30%,可以生化的;BOD5/CODcr≤30%,可生化性差或不宜生化。
用BOD5/CODcr比值评价废水好氧可生化性,方法简便可行,但有其局限性。……