第一作者付强男,博士,副研究员,1975年11月生
含气率对AP1000核主泵影响的非定常分析
付强,习毅,朱荣生,袁寿其,王秀礼
(江苏大学流体机械工程技术研究中心,江苏镇江212013)
摘要:为研究含气率对核主泵内部各点压力影响规律及不同泵进口含气率时气体在核主泵内的分布情况,在对核主泵进行水力设计与三维建模基础上,采用CFD技术对核主泵失水事故气液两相流工况进行瞬态数值模拟。通过模拟不同泵进口含气率时核主泵内部流动的瞬态特性,研究泵进口含气率对泵内各点压力的影响规律及气体分布。结果表明,泵进口含气率增大泵内各点压力随之降低;含气率小于0.1时其对监测点压力脉动主频振幅影响不大,且泵内气体聚集现象不明显;含气率大于0.2后监测点压力脉动主频振幅稍有下降,且泵内开始出现明显的气体聚集现象。
关键词:核主泵;气液两相;含气率;压力脉动
收稿日期:2013-10-21修改稿收到日期:2014-03-27
中图分类号:Th113文献标志码:A
基金项目:国家自然科学基金(11402232);国家“十二五”科技支撑项目 (2012BAD24B01);宁波自然科学基金(2011A610154)
AP1000 nuclear main pump internal unsteady analysis under gas-liquid two phase condition
FUQiang,XIYi,ZHURong-sheng,YUANShou-qi,WANGXiu-li(Technical and Research Center of Fluid Machinery Engineering, Jiangsu University, Zhenjiang 212013,China)
Abstract:In order to study the influence of different inlet gas volume fraction on various point pressures in a nuclear main pump and the gas distribution in this pump, based on the hydraulic design and three-dimensional modeling of the nuclear main pump, CFD technology was used to simulate the nuclear main pump transient flow characteristics under loss of coolant accident(LOCA) and liquid-gas two-phase condition. By simulating the transient characteristis of the internal flow in the nuclear main pump, the effects of inlet gas volume fraction on pressures of many points in the pump and the gas distribution inside were clarified. The results showed that the pressures in the pump decrease with increase in pump inlet gas rate; gas rate has little effect on the pressure fluctuation amplitude of the monitored point at the main frequency and the gas gathering is not obvious when the inlet gas volume fraction is less than 0.1; gas rate has an obvious effect on the above amplitude and gas gathering is obvious when the inlet gas volume fraction is more than 0.2.
Key words:nuclear reactor coolant pump; gas-liquid two-phase; gas volume fraction; pressure pulsation
核反应堆冷却剂循环泵(简称“核主泵”)是核电站回路系统中唯一高速旋转设备,也是关键核动力设备之一。位于反应堆与蒸汽发生器之间,主要用于驱动核岛内高温、高压及强辐射冷却剂在回路循环,将反应堆芯核裂变产生的热能传递给蒸汽发生器产生蒸汽,推动核岛外的汽轮机发电[1-2]。在地震、剧烈震动及过高管路压力等突发情况下可导致管道破裂,即失水事故发生,管道破裂后管路内压力将迅速下降,当压力低于冷却剂的汽化压力时冷却剂发生汽化现象,导致流入核主泵的冷却剂不再是单一液相,成为汽、液相混合物。……