大容量通信设备能耗测试的简易方法研究

2017-03-13 01:46:10李韶英庄湛海陈昊
移动通信 2017年1期

李韶英+庄湛海+陈昊

【摘 要】为了降低大容量设备能耗测试的成本和难度,简化测试工作,在传统测试方法的基础上,通过分析历史测试数据,研究了电源转化率稳定后业务板卡与整机能耗的线性模型,提出了大容量通信设备能耗测试的简易方法,并经过实验室测试验证了该方法的可行性。

【关键词】大容量设备 能耗测试 电源转化率

Research on a Simple Method of the Energy Consumption Test

for the Large Capacity Communication Equipment

[Abstract] In order to reduce the cost and difficulty of large capacity equipment energy consumption test and simplify the testing work, the traditional testing method was analyzed in this paper. Based on the historical data of the energy consumption test, the linear model of service card and equipment energy consumption in the case of the stable power conversion rate was studied to propose a simple method of the energy consumption test for the large capacity communication equipment. Laboratory tests validate the feasibility of the proposed method.

[Key words]large capacity equipment energy consumption test power conversion rate

1 引言

随着互联网业务的爆炸式增长,通信设备向着高集成度、大容量方向发展。目前通信设备的槽位和设计容量越来越大,涉及的产品单板、模块和部件等检测物料数量多,测试环境复杂,这些都无疑增加了测试的难度,并造成测试的人力和物料成本的提高,因此迫切需要在日常的测试工作中研究探索切实可行的大容量通信设备的能耗测试方法。本文在传统测试方法的基础上,提出了大容量通信设备能耗测试的简易方法,以此降低大容量设备能耗测试的成本和难度,简化测试工作。

2 大容量通信设备能耗测试传统方法

由于通信设备的能效水平受设备的配置、业务流量大小以及设备的应用环境等因素的影响,充分考虑到产品的配置及流量对产品能效水平的影响,通常采用产品综合能效比的方法评价设备的能效水平。综合能效比计算方法如下:

参数说明:EER为设备综合能效比;Ti为产品在某一固定配置模型下的最大吞吐量;Pi为产品在某一固定配置模型下的设备综合功耗;Ci为产品在某一固定配置模型的应用权重,C1~Cn之和等于1;……