武晓航 杨鑫焱
【摘 要】阻尼器支架是关系到核电厂管道设备安全运行的重要支吊架类型,阻尼器的结构复杂,成本很高,随着抗震设计规范的升版,反应谱法有了进一步的优化。论文以某核电厂安全注入系统的管道力学计算为例,介绍通过应用不同的反应谱计算方法,对管道系统进行应力分析,并对阻尼器支架的设置进行优化设计,计算结果表明,通过使用新版RG1.61规范的计算方法,能够取消部分阻尼器支架。
【Abstract】Damper support is an important support hanger type for nuclear power plant pipeline equipment safety operation. The structure of damper is complex, and the cost is very high. With the upgrade of seismic design standard, the response spectrum method has been further optimized. This paper takes the pipeline mechanics calculation of a nuclear power plant safety injection system as an example, the stress analysis of the pipeline system is carried out by applying different response spectrum calculation methods, and the optimal design of the damper support is carried out. The calculation results show that: by using the new version of the RG1.61 standard calculation method, some damper brackets can be cancelled.
【关键词】阻尼器;抗震;反应谱
【Keywords】damper; anti-seismic; response spectrum
【中图分类号】TM11 【文献标志码】A 【文章编号】1673-1069(2017)06-0167-02
1 引言
阻尼器是关系到核电管道设备安全的重要支吊架类型。其主要功能是防止管道和设备在受到地震及其他偶然性动态载荷时被动态载荷破壞,在由于温度效应引起的管道位移下,阻尼器支架不发生作用,当发生地震、管道破裂、安全阀开启、水锤等工况时,阻尼器支架作为刚性约束保护管道或设备的安全。
阻尼器根据结构形式可以分为机型阻尼器和液压阻尼器,由于其结构复杂,用于核电厂使用的阻尼器对其结构的可靠性有很高的要求,需要进行后期维护,因此十分昂贵,在电站的初步设计中,为考虑成本,尽量调整通过管道或者支吊架的布置保证管道系统和设备的安全,减少不必要的阻尼器的使用。
2 反应谱法
在管道的抗震计算中,一般有等效静力法,反应谱法和时程分析法[1]。等效静力法适用于刚性部件,其固有频率要高于截断频率;时程分析法能够准确模拟结构的动态效应,多用于复杂结构以及一些需要考虑非线性问题的结构,计算耗时长,对计算机要求较高。……