摘要 :目的 对市场上医用棉签出现变黄的样品进行原因分析。方法 在医用棉签的行业标准的指导下,通过选择无菌、醚中可溶物、金属离子检测对试样进行生物、化学分析。结果 经金属离子分析,发黄棉签的铁离子偏高,且该厂家的产品中的铁、锰离子也较其他厂家产品偏高。结论 结合其生产工艺流程,考虑其生产设备的维护,故推断棉签发黄是因其在生产过程沾到微量金属,金属离子的存在致使氧化变黄。

关键词 :医用棉签 变黄 金属离子

Abstract :Objective To analysis the cause of the medical cotton samples appear yellow on the market. Methods Under the guidance of medical Cotton industry standard, by selecting a sterile, ether-soluble, metal ion detection of biological and chemical to analysis samples. Results Through the metal ion analysis,the yellow cotton has higher iron ions than others, and iron, manganese ion product is also higher compared to the manufacturers of the products of other manufacturers. Conclusion Combined with its production process, consider the maintenance of production equipment, it is concluded that the issue of yellow cotton is stained because of trace metals in the production process, resulting in the presence of metal ions in the oxide yellow.

key words :Medical Cotton; Yellow; Metal Ion

伴随着我国医疗卫生水平的逐步提升,医用棉签作为一种常用的医用工具,广泛地用于医疗卫生单位和家庭卫生护理,其在医用消毒、处理伤口、涂抹药水、取样等许多方面都具有不可或缺的地位,因此其质量的好坏直接影响着诊断的准确性及治疗效果,同时也关系着患者的身体健康和合法权益。但目前医用棉签生产企业规模多数较小,生产能力参差不齐,进而导致市场上如此大需求的小产品存在着质量隐患——棉签的脱脂棉部分发黄,且此现象呈现不均匀性,或出现许多发黄点、或是于一小片部位集聚式发黄。本文就市场上出现的医用棉签脱脂棉部分发黄的样品进行相关试验,以期对其进行原因分析。

1. 仪器与试样

1.1 主要仪器与器皿

Agilent 7500A ICP-MS、AR224CN电子天平、GHP-9270隔水式恒温培养箱、WGL-125B电热鼓风干燥箱、索氏提取器。

1.2 试药与试剂

氯化钠(AR 500g/瓶,天津大茂化学试剂厂)、高锰酸钾(AR 500g/瓶,成都市科龙化工试剂厂)、乙醚(AR 500mL/瓶,国药集团)、硝酸(AR 500mL/瓶,成都市科龙化工试剂厂)、硫酸(AR 500mL/瓶,成都市科龙化工试剂厂);……