巩文庆 曹溢
【摘要】 目的 探討比较微创撬拨复位空心拉力螺钉固定与钢板内固定治疗SandersⅡ型、Ⅲ型跟骨骨折的疗效。方法 57例(65足)SandersⅡ型、Ⅲ型跟骨骨折患者, 随机分为撬拨组(给予微创撬拨复位空心拉力螺钉固定)与切开组(给予常规钢板内固定), 其中撬拨组22例(24足, Ⅱ型18足, Ⅲ型6足), 切开组35例(41足, Ⅱ型29足, Ⅲ型12足), 评价两组的治疗效果。结果 57例患者均获随访, 随访时间10~18个月, 撬拨组手术时间(67.52±7.56)min、术中出血量(49.32±5.24)ml、切口愈合时间(6.64±1.45)d
均优于切开组(103.56±14.96)min、(123.47±19.24)ml、(13.12±1.56)d, 差异有统计学意义(P<0.05)。术后两组Bohler角、Gissane角恢复情况、并发症及术后足部功能恢复优良情况比较差异无统计学意义(P>0.05), 切开组3例出现坏死。结论 微创撬拨复位空心拉力螺钉固定治疗SandersⅡ型、Ⅲ型跟骨骨折, 术中出血少、手术时间短、术后并发症少, 是治疗跟骨骨折(SandersⅡ型、Ⅲ型)的有效手术方式。
【关键词】 跟骨骨折;微创;空心螺钉;内固定
DOI:10.14163/j.cnki.11-5547/r.2016.33.002
Analysis of curative effects by minimally invasive poking reduction cannulate lag screw and plate internal fixation in the treatment of Sanders Ⅱ and Ⅲ type calcaneal fracture GONG Wen-qing, CAO Yi. Department of Orthopedics, Hefei City Second Peoples Hospital, Hefei 230000, China
【Abstract】 Objective To investigate and compare curative effects between minimally invasive poking reduction cannulate lag screw and plate internal fixation in the treatment of Sanders Ⅱ and Ⅲ type calcaneal fracture. Methods A 57 patients (65 feet) with Sanders Ⅱ and Ⅲ type calcaneal fracture were randomly divided into poking reduction group (received minimally invasive poking reduction cannulate lag screw for fixation) and incision group (received conventional plate internal fixation), with 22 cases in the poking reduction group (24 feet, 18 Ⅱ type feet and 6 Ⅲ type feet) and 35 cases in the incision group (41 feet, 29 Ⅱ type feet and 12 Ⅲ type feet). Curative effects were evaluated in both groups. Results All 57 patients received follow-up for 10~18 months. The poking reduction group had operation time as (67.52±7.56) min, intraoperative bleeding volume as (49.32±5.24) ml, and incision healing time as (67.52±7.56) min, which were all better than (103.56±14.96) min,
(123.47±19.24) ml and (13.12±1.56) d in the control group. Their difference had statistical significance (P<0.05). There was no statistically significant difference of postoperative recovery of Bohler angle, Gissane angle, complications and foot function between the two groups (P>0.05). There were 3 cases with necrosis in the incision group. Conclusion Minimally invasive poking reduction cannulate lag screw for fixation in treating Sanders Ⅱ and Ⅲ type calcaneal fracture shows few intraoperative bleeding volume, short operation time and few postoperative complications. It is an effective operation in treating calcaneal fracture (Sanders Ⅱ and
Ⅲ type).
【Key words】 Calcaneal fracture; Minimally invasive; Cannulate screw; Internal fixation
跟骨骨折臨床多见, 约占跗骨骨折的60%, 其中约60%~ 75%为关节内骨折, 多由高处坠落伤引起[1]。移位的关节内跟骨骨折若是处理不当, 常会出现足部畸形、距下关节痛甚至足部功能障碍等后遗症。目前对于跟骨骨折的治疗尚无统一的观点, SandersⅡ型、Ⅲ型跟骨骨折的治疗仍存在争议。本科2013年7月~2015年11月收治SandersⅡ型、Ⅲ型跟骨骨折患者共57例(65足), 采用微创和传统两种手术方式治疗, 其疗效分析报告如下。
1 资料与方法
1. 1 一般资料 收集本科2013年7月~2015年11月手术治疗的SandersⅡ型、Ⅲ型跟骨骨折患者共57例(65足), 随机分为撬拨组22例(24足, Ⅱ型18足, Ⅲ型6足), 切开组35例(41足, Ⅱ型29足, Ⅲ型12足)。撬拨组中男16例, 女6例, 年龄19~57岁, 平均年龄35.6岁, 致伤原因:高处坠落伤19例, 车祸伤3例。……