血站内、外献血者丙氨酸氨基转移酶检测结果比对及影响因素分析

2017-09-22 10:25:28赵建鹏杨晓芽杨秀萍
中国医药导报 2017年22期
关键词:影响因素

赵建鹏 杨晓芽 杨秀萍

[摘要] 目的 比较站内和站外献血者丙氨酸氨基转移酶(ALT)检测结果,制订相应的措施以保证不同仪器设备检测结果的一致性。 方法 采用全自动生化仪日立7100和半自动生化仪Photometer 4040对同一献血者进行ALT测定;以全自动生化仪日立7100的检查结果为标准结果X,半自动生化仪Photometer 4040的检测结果为待评价结果Y(采血车上Photometer 4040为Y1,站内Photometer 4040为Y2)计算Yn减去X的差值dn,比较d1和d2的差异,并做折线图直观反映站内、站外ALT检测结果的差异,对造成差异的影响因素进行分析。 结果 日立7100和血站外4040检测结果差值d1为(5.07±4.33),日立7100和血站内4040检测结果差值d2为(2.40±1.39),两者比较差异有统计学意义(t=7.513,P < 0.05)。d1的折线图波动幅度明显大于d2。 结论 站外半自动生化仪ALT检测结果的不稳定性明显高于站内检测结果,造成这一结果的原因可能为实验操作的环境因素,仪器的电流、电压的稳定性,末梢血采集过程中出现溶血等血样的问题等。

[关键词] 献血者;丙氨酸氨基转移酶;生化分析仪;影响因素

[中图分类号] R446.111 [文献标识码] A [文章编号] 1673-7210(2017)08(a)-0121-04

[Abstract] Objective To compare the detection results of alanine aminotransferase (ALT) test of blood donors inside and outside the station, in order to develop corresponding measures to ensure the consistency of the results of different instruments and equipments. Methods The same donors′ blood ALT were measured by automatic biochemical analyzer Hitachi 7100 and semi-automatic biochemical analyzer Photometer 4040 respectively. The results obtained by the Hitachi 7100 were taken as standard results X, and the results of Photometer 4040 were takend as unevaluated results Y (the results of Photometer 4040 on the donation car were Y1; the results of Photometer 4040 in the station were Y2). The dn was calculated by Yn subtracting X, the differences between d1 and d2 were compared, and line charts of dn were made to directly reflect differences in ALT testing results outside and inside the station. The factors leading to different results were analyzed. Results Difference value d1 of Hitachi 7100 and outside blood station 4040 test results was (5.07±4.33), difference value d2 of Hitachi 7100 and inside blood station 4040 test results was (2.40±1.39), the difference was significant (t=7.513, P < 0.05). The fluctuation range of the d1 line chart was obviously higher than that of d2 line chart. Conclusion The instability of the ALT results obtained by semiautomatic biochemical analyzer outside the station is significantly higher than that inside the station. There are many reasons for this result, such as environmental factors of experimental operation, the stability of electric current and voltage of instrument and hemolysis as well as other blood problems in blood collection process.

[Key words] Blood donors; ALT; Biochemical analyzer; Influential factors

無偿献血者所献的血液必须经过丙氨酸氨基转移酶(ALT)、乙型肝炎表面抗原(HBsAg)、丙型肝炎抗体(Anti-HCV)、梅毒螺旋体(TP)和艾滋病毒抗体(Anti-HIV)等项目的检测以确保血液安全。其中,ALT是世界卫生组织推荐用于检测肝功能损害的敏感检测指标,由于我国是肝炎高发地区,故ALT也是无偿献血者血液检测的主要项目之一[1]。ALT分布广泛,于全身各组织中均能检测到,尤其在肝脏中的含量最丰富。正常情况下ALT在血清中含量很低,当肝细胞受损时,血清ALT的浓度会升高,其中,1%肝细胞坏死,血清中酶活性增高1倍。此外,当肝细胞通透性增加时,转氨酶也可从肝细胞中释出,使血清中酶含量增高。因此,当轻、中度肝损伤时,由于肝细胞的坏死和肝细胞膜通透性增高等因素,肝细胞胞浆内ALT释放入血,导致血液中ALT升高。……

登录APP查看全文

猜你喜欢
影响因素
房地产经济波动的影响因素及对策
零售银行如何赢得客户忠诚度
医保政策对医疗服务价格影响因素的探讨
东林煤矿保护层开采瓦斯抽采影响因素分析
影响农村妇女政治参与的因素分析
高新技术企业创新绩效影响因素的探索与研究
水驱油效率影响因素研究进展
突发事件下应急物资保障能力影响因素研究
中国市场(2016年36期)2016-10-19 03:54:01
环卫工人生存状况的调查分析
中国市场(2016年35期)2016-10-19 02:30:10
农业生产性服务业需求影响因素分析
商(2016年27期)2016-10-17 07:09:07