徐建军 刘新
摘要:中国是动植物油脂的消费大国,每年需要进口大量动植物油脂满足需求。在油脂贸易中,船舱和岸罐的交接由于标准计量器具精度的不一致,交接不规范,未按操作规程操作,以及环境条件的影响等都有可能造成船舱计重结果和岸罐计重结果存在较大差异,从而可能因两者结算方式差异太大引发经济纠纷。论文将通过案例就船舱计量与岸罐计量交接中产生的差异原因作初步分析和探讨。
关键词:船舱计量 岸罐计量 差异 分析
Study on the Difference of "THERESA DUMAI" Tanker Cabin Measurement and Bank Tank Measurement
Xu Jianjun( Jingang Customs)
Liu Xin (Zhangjiagang Customs)
Abstract: China is a big consumer of animal and vegetable oils and fats. It needs to import a large amount of animal and vegetable oils to meet the demand every year. In the oil trade, the transfer of the ship's cabin and the shore tank is inconsistent due to the accuracy of the standard measuring instruments, the handover is not standardized, the operation is not in accordance with the operating procedures, and the influence of environmental conditions may cause the cabin weight measurement results and the shore tank weighting results. The big difference may lead to economic disputes due to the difference in settlement methods between the two. This paper will make a preliminary analysis and discussion on the reasons for the differences between the cabin measurement and the shore tank measurement handover.
Key words: cabin measurement, shore tank measurement, difference, analysis
1 引言
近日,海关查验人员在对一艘图瓦卢籍进口油轮“THERESA DUMAI”进行容量计量时发现,装载于该轮提单总数为4999.676 t的精炼棕榈液油船舱计量结果为5037.829 t,比提单数多了38.153 t,而卸入岸罐后计量结果为4952.401 t,却比提单数少了47.275 t,岸罐计量结果和船舱计量结果相差了85.428 t,兩者差重率高达1.7%。后该海关查验人员通过对装货港及各项鉴定数据的对比分析,上述两者计量差异主要是由于船舱舱容虚高、装货港密度偏大、卸货不净、卸货管道滞留等原因造成。查验人员以岸罐计量数据及时出具重量(质量)证书,帮助企业对外提赔32.5万元。
2 误差分析
2.1 船舱和岸罐的检定误差
经国家计量部门检定的船舶舱和岸罐均属于国家三等标准计量器具,但它们的计量精度是不同的,船舱标准容量的相对误差:形状规则船舱为±0.3%,形状不规则船舱为±0.5%;岸罐检定的总不确定度不大于0.1%。可见,岸罐精度要高于船舱计量精度,按《中华人民共和国计量法》规定,应以精度高的岸罐为准,经常发生重大短重或船舱计量与岸罐计量有重大差异的船舶,不宜用船舱计量结果出证。……